Comparison of three manual ventilation devices using an intubated mannequin.

نویسندگان

  • S G Hussey
  • C A Ryan
  • B P Murphy
چکیده

OBJECTIVE To compare three devices for manual neonatal ventilation. DESIGN Participants performed a two minute period of ventilation using a self inflating device, an anaesthesia bag with attached manometer, and a Neopuff device. An intubated neonatal mannequin, approximating a 1 kg infant with functional lungs, was used for the study. Target ventilation variables included a rate of 40 breaths per minute, peak inspiratory pressure (PIP) of 20 cm H2O, and positive end expiratory pressure (PEEP) of 4 cm H2O. The circuit was attached to a laptop computer for data recording. RESULTS Thirty five participants were enrolled, including consultant neonatologists, paediatricians, and anaesthetists, paediatric and anaesthetic registrars, and neonatal nurses. The maximum PIP recorded using the self inflating bag, anaesthetic bag, and Neopuff device were 75.9, 35.5, and 22.4 cm H2O respectively. There were significant differences between the devices for mean PIP (30.7, 18.1, and 20.1 cm H2O), mean PEEP (0.2, 2.8, and 4.4 cm H2O), mean airway pressure (7.6, 8.5, and 10.9 cm H2O), % total breaths < or = 21 cm H2O PIP (39%, 92%, and 98%), and % total breaths > or = 30 cm H2O PIP (45%, 0, and 0). There was no difference between doctors and allied health professionals for the variables examined. CONCLUSION The anaesthetic bag with manometer and Neopuff device both facilitate accurate and reproducible manual ventilation. Self inflating devices without modifications are not as consistent by comparison and should incorporate a manometer and a PEEP device, particularly when used for resuscitation of very low birthweight infants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of efficacy of three devices of manual positive pressure ventilation: a mannequin-based study

BACKGROUND We compared the efficacy of and consistency in manual ventilation by trained healthcare professionals using three devices: self-inflating bag, flow-inflating bag, and T-piece resuscitator. METHODS Prospective analytical study at a level III Neonatal unit of a tertiary care hospital. Forty participants (consultants, postgraduates, interns, and neonatal nurses - 10 each) manually ven...

متن کامل

An Experience with Manual Ventilation in Respiratory Paralysis Due to Indian Common Krait (Bungarus Caeruleus) Bite

Background: Bungarus caeruleus (common krait) bite during monsoon season is common in northwest India. Respiratory failure is responsible for high mortality in the victims. In this study we report our experience with manual ventilation using bag valve mask (BVM) in patients with neuroparalysis due to common krait bite.  Methods:This prospective study was conducted between June 2009 and December...

متن کامل

Neonatal resuscitation 3: manometer use in a model of face mask ventilation.

BACKGROUND Adequate ventilation is the key to successful neonatal resuscitation. Positive pressure ventilation (PPV) is initiated with manual ventilation devices via face masks. These devices may be used with a manometer to measure airway pressures delivered. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal...

متن کامل

Manual ventilation and risk of barotrauma: primum non nocere.

Optimizing bag ventilation during cardiopulmonary resuscitation or ventilation of an unprotected airway1 is mandatory to minimize the risk of pulmonary complications and the occurrence of gastric inflation due to excessive airway pressure.2 Numerous studies have underlined the difficulty of providing safe and effective bag ventilation in these situations, and new devices have been marketed to h...

متن کامل

Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.

BACKGROUND The key to successful neonatal resuscitation is effective ventilation. Little evidence exists to guide clinicians in their choice of manual ventilation device or face mask. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal resuscitation. AIM To compare the efficacy of (a) the Laerdal infant resu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 89 6  شماره 

صفحات  -

تاریخ انتشار 2004