Biomechanical Evaluation of Pedicle Screw-Based Dynamic Stabilization Devices for the Lumbar Spine: A Systematic Review
نویسندگان
چکیده
STUDY DESIGN This study is a systematic review of published biomechanical studies involving pedicle screw-based posterior dynamic stabilization devices (PDS) with a special focus on kinematics and load transmission through the functional spine unit (FSU). METHODS A literature search was performed via the PubMed online database from 1990 to 2008 using the following key words: "biomechanics," "lumbar dynamic stabilization," "Graf system," "Dynesys," and "posterior dynamic implant." Citations were limited to papers describing biomechanics of pedicle screw-based PDS devices currently available for clinical use. Studies describing clinical experience, radiology, and in vivo testing were excluded from the review. Parameters measured included kinematics of the FSU (range of motion (ROM), neutral zone (NZ), and location of the center of rotation) and load transmission through the disk, facets, and instrumentation. RESULTS A total of 27 publications were found that concerned the biomechanical evaluation of lumbar pedicle screw-based dynamic stabilization instrumentation. Nine in vitro experimental studies and 4 finite element analyses satisfied the inclusion criteria. The Dynesys implant was the most investigated pedicle screw-based PDS system. In vitro cadaveric studies mainly focused on kinematics comparing ROM of intact versus instrumented spines whereas finite element analyses allowed analysis of load transmission at the instrumented and adjacent levels. CONCLUSION Biomechanical studies demonstrate that pedicle screw-based PDS devices limit intervertebral motion while unloading the intervertebral disk. The implant design and the surgical technique have a significant impact on the biomechanical behavior of the instrumented spinal segment. The posterior placement of such devices results in non-physiologic intervertebral kinematics with a posterior shift of the axis of rotation. Biomechanical studies suggest that the difference at the adjacent level between investigated dynamic devices and rigid stabilization systems may not be as high as reported. Finally, additional investigations of semirigid devices are needed to further evaluate their biomechanical properties compared to soft stabilization PDS systems.
منابع مشابه
Pedicle Screw-Based Posterior Dynamic Stabilization: Literature Review
Posterior dynamic stabilization (PDS) indicates motion preservation devices that are aimed for surgical treatment of activity related mechanical low back pain. A large number of such devices have been introduced during the last 2 decades, without biomechanical design rationale, or clinical evidence of efficacy to address back pain. Implant failure is the commonest complication, which has result...
متن کاملBiomechanical comparison of unilateral semi-rigid and dynamic stabilization on ovine vertebrae.
Using the unilateral pedicle screw fixation was thought to decrease the stiffness of the fixed segments. Various prospective, randomized studies were performed to determine whether unilateral pedicle screw fixation provides the necessities of bilateral fixation in one- or two-segment lumbar spinal fusion. In this study, four different unilateral pedicle screw fixation systems were evaluated to ...
متن کاملThe Cortical Bone Trajectory: An Alternative to Traditional Pedicle Screw Fixation - A Review
The cortical based trajectory for pedicle screw fixation of the lumbar spine is not a novel as it once was. This is a review of the background, indications, advantages, disadvantages of cortical based trajectory pedicle screw fixation with an emphasis on biomechanical evidence and recent clinical studies which only now are just coming to light.
متن کاملComparison of Supplementary Posterior Fixations for Two-Level ALIF with Stand-Alone Cages
INTRODUCTION: Structural cages have been widely used in recent years to maintain motion segment height and stability in anterior lumbar interbody fusion (ALIF). High rate of clinical success and radiological fusion rate have been reported following single-level fusion using these cages. However, many biomechanical studies report insufficient stability, especially with extension loading. Posteri...
متن کاملRole of Dynesys as Pedicle-Based Nonfusion Stabilization for Degenerative Disc Disorders
Posterior nonfusion pedicle-screw-based stabilization remains a controversial area of spine surgery. To date, the Dynesys system remains the most widely implanted posterior nonfusion pedicle screw system. We review the history of Dynesys and discuss clinical outcome studies and biomechanical evaluations regarding the Dynesys system. Indications for surgery and controversies are discussed. Recom...
متن کامل