Signals consistent with microbubbles detected in legs of normal human subjects after exercise.
نویسندگان
چکیده
Exercise may produce micronuclei (presumably gas-filled bubbles) in tissue, which could serve as nucleation sites for bubbles during subsequent decompression stress. These micronuclei have never been directly detected in humans. Dual-frequency ultrasound (DFU) is a resonance-based, ultrasound technique capable of detecting and sizing small stationary bubbles. We surveyed for bubbles in the legs of six normal human subjects (ages 28-52 yr) after exercise using DFU. Eleven marked sites on the left thigh and calf were imaged using standard imaging ultrasound. Subjects then rested in a reclining chair for 2 h before exercise. For the hour before exercise, a series of baseline measurements was taken at each site using DFU. At least six baseline measurements were taken at each site. Subjects exercised at 80% of their age-adjusted maximal heart rate for 30 min on an upright bicycle ergometer. After exercise, the subjects returned to the chair, and multiple postexercise measurements were taken at the marked sites. Measurements continued until no further signals consistent with bubbles were returned or 1 h had elapsed. All subjects showed signals consistent with bubbles after exercise at at least one site. The percentage of sites in a given subject showing signals significantly greater than baseline (P < 0.01) at first measurement ranged from 9.1 to 100%. Overall, 58% of sites showed signals consistent with bubbles at the first postexercise measurement. Signals decreased over time after exercise. These data strongly suggest that exercise produces bubbles detectable using DFU.
منابع مشابه
Relationship between exercise-induced heart rate increase and the formation of microbubbles and high-intensity transient signals in mechanical heart valve implanted patients
INTRODUCTION The formation and collapse of vapor-filled bubbles near a mechanical heart valve is called cavitation. Microbubbles can be detected in vivo by doppler ultrasonography (USG) as HITS (high intensity transient signals) in cranial circulation. We investigated the relationship between exercise induced heart rate increase and HITS formation in cranial circulation. MATERIAL AND METHODS ...
متن کامل\"DOMINANCY\" IN THE SECOND SOMATOSENSORY AREA REVEALED BY MAGNE TOENCEPHALOGRAPHY
The second somatosensory area (SlI) has been studied both by electrical evoked potentials24 and magnetoencephalography (MEG)5 Magnetic evoked fields of contralateral primary somatosensory and ipsilateral second somatosensory cortices of 12 normal subjects were recorded in response to median nerve electrical stimulation by means of a single magnetometer. We detected. in addition to the usua...
متن کاملVariations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy
Background To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...
متن کاملProvoked right-to-left shunt in patent foramen ovale associates with ischemic stroke in posterior circulation.
BACKGROUND AND PURPOSE Right-to-left shunt (RLS) via the patent foramen ovale is an important cause of cryptogenic stroke. The Valsalva maneuver provokes or enhances RLS, but RLS can also occur during normal respiration. This study examined whether the ischemic lesion pattern differs depending on the character of RLS. METHODS All consecutive patients with a patent foramen ovale (diagnosed by ...
متن کاملMicrobubble detection following hyperbaric chamber dives using dual-frequency ultrasound.
Venous gas emboli (VGE) can be readily detected in the bloodstream using existing ultrasound methods. No method currently exists to detect decompression-induced microbubbles in tissue. We hypothesized that dual-frequency ultrasound (DFU) could detect these microbubbles. With DFU, microbubbles are driven with two frequencies: a lower "pump" (set to the resonant frequency of the desired bubble si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 108 2 شماره
صفحات -
تاریخ انتشار 2010