SCIENTIFIC REPORT Interocular amplitude differences of the full field electroretinogram in normal subjects

نویسندگان

  • Y Rotenstreich
  • G A Fishman
  • R J Anderson
  • D G Birch
چکیده

Aims: To determine the interocular amplitude response difference of the electroretinogram (ERG) in normal subjects. Methods: 79 subjects, without retinal changes of clinical significance, underwent ERG testing. They included 63 men and 16 women, with a mean age of 44 (SD 12) years and range of 18–65 years. Isolated rod, scotopic maximal, dark adapted 30 Hz flicker, photopic single flash, and light adapted 30 Hz flicker responses were recorded in both eyes fol lowing the Internat ional Society for Clinical Electrophysiology of Vision (ISCEV) standard protocol. The interocular percentage differences of the ERG b-wave amplitudes were calculated and presented as percentiles (25th, 50th, 75th, 95th), means (SD), and medians. Results: The median interocular percentage differences in the b-wave amplitudes for the above ERG stimulus responses were 10%, 8%, 10%, 11%, and 10%, respectively. The mean interocular percentage differences were 11%, 11%, 12%, 13%, and 14%. The 95th percentiles for the interocular percentage differences were 28%, 27%, 36%, 33%, and 35%, respectively. Conclusions: The interocular percentage differences in the ERG b-wave amplitudes for five different stimulus responses were similar in our cohort of individuals without clinically significant retinal changes and ranged from a median of 8– 11% and a 95th percentile of 27–36%. Our findings should be useful for determining sample sizes in future therapeutic trials on retinal diseases with monocular therapeutic strategies and may also have application for the more accurate detection of asymmetric retinal disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interocular amplitude differences of the full field electroretinogram in normal subjects.

AIMS To determine the interocular amplitude response difference of the electroretinogram (ERG) in normal subjects. METHODS 79 subjects, without retinal changes of clinical significance, underwent ERG testing. They included 63 men and 16 women, with a mean age of 44 (SD 12) years and range of 18-65 years. Isolated rod, scotopic maximal, dark adapted 30 Hz flicker, photopic single flash, and li...

متن کامل

Hemifield pattern electroretinogram in ocular hypertension: comparison with frequency doubling technology and optical coherence tomography to detect early optic neuropathy

BACKGROUND To assess the sensitivity and specificity of hemifield pattern electroretinogram (HF-PERG) for detecting early retinal ganglion cell (RGC) damage in ocular hypertensive (OH) patients. METHODS Fifty-two OH patients (mean age 56±9.6 years) with an intraocular pressure (IOP) .21 mmHg were assessed. All subjects underwent HF-PERG, optical coherence tomography (OCT), and frequency doubl...

متن کامل

The b-wave of the dark adapted flash electroretinogram in patients with advanced asymmetrical glaucoma and normal subjects.

AIMS To evaluate whether the b-wave of the dark adapted flash electroretinogram (ERG) is affected by glaucomatous damage. METHODS ERGs were recorded in 35 patients aged 33-65 years with advanced asymmetrical glaucomas (interocular difference of perimetric defects (mean deviation) >2 dB between the two fellow eyes of the glaucoma patients, primary and secondary open angle and low tension glauc...

متن کامل

The a-wave of the dark adapted electroretinogram in glaucomas: are photoreceptors affected?

AIMS To evaluate whether the a-wave of the dark adapted flash electroretinogram (ERG) is affected by glaucomatous damage. METHODS ERGs were recorded in 20 patients (age 33-65 years) with advanced glaucomas (primary and secondary open angle and low tension glaucomas) and 20 normals using a ganzfeld stimulus. After 30 minutes of dark adaptation and pupil dilatation to at least 7.5 mm in diamete...

متن کامل

Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern Iran

Background: Electroretinography (ERG) is known as a diagnostic test for evaluating the performance of different layers of the retina. Its normal values maybe different in different populations. Objectives: Determining the normal values of ERG parameters in patients presenting to an ophthalmologic center in Guilan in northern Iran. Materials and Methods: Fifty-five people presenting to a teach...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003