Clinical usefulness of Tc-99m hexakis 2-methoxyisobutyl isonitrile gated spect in patients with dilated cardiomyopathy: retrospective analysis.

نویسندگان

  • Zahid Rahman Khan
  • Nat E Watson
  • Afshan Zahid Khan
چکیده

BACKGROUND In Dilated cardiomyopathy the heart is enlarged and ventricles are dilated. Gated myocardial perfusion single photon emission computed tomography is considered state of the art for myocardial perfusion imaging. A retrospective analysis was conducted to evaluate patients with dilated cardiomyopathy with Tc-99m sestamibi gated myocardial perfusion single photon emission computed tomography to evaluate its clinical utility. METHODS A 10 year retrospective medical record review was done from 1991 to 2001 at Wake Forest University, North Carolina, USA. Eligibility criteria included a diagnosis of dilated cardiomyopathy and availability of coronary angiography and Tc-99m sestamibi cardiac imaging results. 26 cases were selected for the final review and inclusion in the study. The study was done with standard protocols for cardiac sestamibi imaging. RESULTS A total of 26 cases were included in the final analysis. Cases were divided into two main groups. Group-A included 16 patients with no correlation between Tc-99m sestamibi and cardiac catheterisation reports. Group-B included 10 patients with good correlation between the above tests. There were no significant differences between the left ventricular ejection fraction, angina history, sex distribution and diabetic status between the two groups. We applied Wilcoxon Signed Rank Test and z-test to quantify the difference between the two groups. Data was tabulated and z-test was performed. The calculated p-value was <0.0001. This is significantly less than the tabulated p-value at 5% level of significance, i.e., 1.96. Significant differences exist between Group-A and Group-B. CONCLUSION Tc-99m sestamibi is an excellent agent for investigating myocardial perfusion in dilated cardiomyopathy. The reversible and fixed perfusion defects (small to medium sized) seen in dilated cardiomyopathy after performance of Tc-99m sestamibi gated single photon emission computed tomography imaging may not be due to coronary artery disease. Tc-99m sestamibi single photon emission computed tomography is useful as a routine non-invasive technique to evaluate myocardial function in dilated cardiomyopathy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single Photon Emission Computed Tomography With Technetium-99m Hexakis 2~Methoxyisobutyl Isonitrile in Acute Myocardi~.I Infarction Before and After Thrombolytic Treatment: Assessment of Salvaged Myocardium and Prediction of Late Functional Recovery

Single photon emission computed tomography (SPECT) with technetium-99m hexakis 2-methoxyisobutyl isonitrile was investigated as a method to evaluate the results of intravenous thrombolytic treatment in 14 patients (11 men and 3 women) with acute myocardial infarction admitted to the coronary care unit within 4 h of the onset of symptoms. All patients received an injection of 740 MBq of the trac...

متن کامل

The role of technetium-99m hexakis-2-methoxyisobutyl isonitrile in the detection of neoplastic lung lesions.

OBJECTIVE Our goal was to determine the role of technetium-99m hexakis-2-methoxyisobutyl isonitrile ((99m)Tc-MIBI) in the detection of neoplastic lung lesions. MATERIALS AND METHODS We prospectively studied 79 consecutive patients with indeterminate lung lesion between January 2006 and September 2007. All patients were submitted to (99m)Tc-MIBI single-photon emission chest tomography (SPECT) ...

متن کامل

F-18-2-fluoro-2-deoxyglucose positron emission tomography compared to technetium-99m hexakis-2-methoxyisobutyl isonitrile single photon emission chest tomography in the diagnosis of indeterminate lung lesions.

BACKGROUND (18)FDG-PET plays a significant role in diagnosing malignancy of lung lesions but remains an expensive test available at a limited number of sites in Italy. OBJECTIVE We prospectively compare the diagnostic accuracy of (99m)Tc-MIBI- SPECT and (18)FDG-PET in patients with indeterminate lung lesions to demonstrate that (99m)Tc-MIBI-SPECT may be considered as a valid alternative when ...

متن کامل

Mechanism for abnormal thallium-201 myocardial scintigraphy in patients with left bundle branch block in the absence of angiographic coronary artery disease.

Patients with left bundle branch block (LBBB) often show abnormal images on exercise thallium (T1)-201 scintigraphy without evidence of significant coronary stenosis. We investigated the mechanism for this phenomenon. Six patients with LBBB and without significant coronary stenosis underwent T1-201 SPECT, ECG-gated SPECT imaging with Tc-99m-methoxyisobutyl-isonitrile (MIBI), and atrial pacing s...

متن کامل

Comparison of regional myocardial blood flow and perfusion in dilated cardiomyopathy and left bundle branch block: role of wall thickening.

UNLABELLED Heterogeneous perfusion in left bundle branch block (LBBB) has been demonstrated by (99m)Tc-methoxyisobutylisonitrile (MIBI) SPECT. Locally different contraction is also associated with LBBB. Quantitative analysis of myocardial SPECT is influenced by partial-volume effects depending on systolic wall thickening. Therefore, partial-volume effects may mimic perfusion heterogeneity in LB...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Ayub Medical College, Abbottabad : JAMC

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2010