Glaucoma laser suture lysis.

نویسندگان

  • P Macken
  • Y Buys
  • G E Trope
چکیده

AIM Suture lysis is commonly performed after trabeculectomy to improve bleb function. It is often thought to be an innocuous procedure. This is the first large study to determine the safety of the procedure and compare results with a control group. METHODS Two hundred successive trabeculectomies performed between January 1992 and October 1993 were analysed. RESULTS Ninety nine eyes underwent trabeculectomy and suture lysis; 101 eyes underwent trabeculectomy and did not require postoperative suture lysis. The following complications were noted with suture lysis: flat chambers (13.1%), external aqueous leaks (9%), malignant glaucoma (2%), iris incarceration (2%), and large blebs (2%). All resolved with appropriate management. There was no significant difference in the final postoperative mean pressures between the lysis and the non-lysis groups. CONCLUSION Suture lysis is not an innocuous procedure. However if managed appropriately, complications do not affect the intraocular pressure outcome.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trabeculectomy for open-angle glaucoma in phakic eyes vs in pseudophakic eyes after phacoemulsification: a prospective clinical cohort study.

IMPORTANCE Whether pseudophakic eyes are resistant to trabeculectomy remains unknown. OBJECTIVE To determine the effect of previous phacoemulsification on surgical success of trabeculectomy with mitomycin C for open-angle glaucoma. DESIGN, SETTING, AND PARTICIPANTS Prospective clinical cohort study at Kumamoto University Hospital, Kumamoto, Japan, among patients 55 years or older having ope...

متن کامل

Laser suture lysis through thick blebs using the Blumenthal lens.

L aser suture lysis is commonly performed after trabeculectomy and is titrated to control postoperative flow through the filter to a target intraocular pressure. Originally, the flat edge of a Zeiss 4-mirror lens was used to compress the conjunctiva and Tenon capsule to view the sutures. The Hoskins lens designed for suture lysis improved the view and allowed eyelid elevation for better exposur...

متن کامل

Argon laser suture lysis with different suture materials. An experimental study.

In an in vitro study, 10/0 nylon was found to require a significantly lower laser energy density to produce suture lysis following a single shot than either 10/0 Dacron or 10/0 prolene. Nylon and Dacron monofilament sutures ruptured at reproducible energy levels without significant observable changes at subthreshold irradiation. Prolene, however, was observed to stretch at energy levels below t...

متن کامل

[Late and recurrent serous choroidal detachment after trabeculectomy: case report].

A case of an 85 year-old white man with bilateral senile cataract and advanced primary open-angle glaucoma uncontrolled with maximal medical therapy, asteroid hyalosis in OD and age-related macular degeneration in OS, submitted to a phacotrabeculectomy OU with mitomycin-C is reported. Because the surgery failed in both eyes, even after laser suture lysis, 5-FU injections and needling, it was ne...

متن کامل

Comparison of laser and circumlimbal suture induced elevation of intraocular pressure in albino CD-1 mice

Animal models of ocular hypertension are important tools for glaucoma studies. Both acute transient models and chronic models of ocular hypertension may be useful to investigate specific aspects of neurodegeneration. In this study, we compare the intraocular pressure (IOP) and inner retinal changes induced by 1) laser photocoagulation of both episcleral veins and limbal vessels and 2) circumlim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 80 5  شماره 

صفحات  -

تاریخ انتشار 1996