Comparison of Clinical and Radiological Results according to Glenosphere Position in Reverse Total Shoulder Arthroplasty: A Short-term Follow-up Study
نویسندگان
چکیده
BACKGROUND In a previous biomechanical study, eccentric glenospheres with more inferior position of the center of rotation were shown to improve range of motion and reduce the incidence of scapular notching after reverse total shoulder arthroplasty (RSA). The purpose of this study was to compare the clinical and radiological results of RSA using an eccentric glenosphere to those using a concentric glenosphere and to determine the usefulness of the eccentric glenosphere. METHODS From 2009 to 2015, we performed a retrospective review of 20 consecutive patients who underwent RSA using a deltopectoral approach. Nine patients underwent RSA using a concentric glenosphere (group A) while 11 had an eccentric glenosphere (group B). The average follow-up period was 13.9 months (range, 12 to 18 months). All glenoid components were placed with 15° of inferior tilt. Clinical results were assessed using the visual analog pain scale score (VAS), the American Shoulder and Elbow Surgeon (ASES) score, the Korean shoulder scoring system (KSS), and the Constant score. On radiological evaluation, prosthesisscapular neck angle (PSNA), peg-glenoid rim distance (PGRD), scapular neck-inferior glenoshere rim distance (inferior glenoshpere overhang), acromion-greater tuberosity (AT) distance, glenoid-greater tuberosity (GT) distance, and severity of notching according to the Nerot-Sirveaux classification were assessed. RESULTS The clinical results improved significantly in both groups, but there was no statistically significant difference between the two groups. A significant intergroup difference was observed with regard to PGRD (24.8 ± 1.6 mm for group A vs. 22.2 ± 1.9 mm for group B; p = 0.002) and inferior glenosphere overhang (2.0 ± 1.7 mm for group A vs. 5.8 ± 1.6 mm for group B; p = 0.000). Seven of 9 patients in group A developed notching compared with 2 of 11 patients in group B (p = 0.022). The other radiological parameters such as inferior tilt and AT and GT distances were not significantly different between two groups. Complications such as loosening and scapular fractures did not occur. CONCLUSIONS The eccentric glenosphere in RSA was more effective in reducing the rate of notching than the concentric glenosphere although clinical outcomes were not significantly different in the short-term follow-up.
منابع مشابه
Inferior glenosphere placement reduces scapular notching in reverse total shoulder arthroplasty.
Scapular notching is a common complication after reverse shoulder arthroplasty and has been associated with poor clinical outcomes. Factors associated with notching include neck shaft angle and glenosphere position. The goal of this study was to evaluate the incidence of notching with an eccentric glenosphere that allows for inferior offset as well as its effect on clinical outcome. The charts ...
متن کاملReverse Total Shoulder Arthroplasty for the Treatment Of Synovial Chondromatosis: A Case Report and Review of the Literature
Synovial chondromatosis affecting the glenohumeral joint is rare. Treatment primarily consists of arthroscopic loose body removal and synovectomy. Shoulder arthroplasty has been mentioned in the literature as a treatment option for patients with coexisting arthritis, although the results have been underreported. The case of an 84-year-old man with long standing synovial chondromatosis of the sh...
متن کاملShort-Term Results of the DePuy Global Unite Platform Shoulder System: A Two-Year Outcome Study
Background: The Global Unite Shoulder System is the next generation of implant from the Depuy Global Shoulderline. The primary feature of the Global Unite is adaptability through the interchangeable modular bodies, modular suturecollars, and stems. Short-term functional and radiographic outcomes of the Global Unite Platform Shoulder Systemwere assessed as well as complication and revision rates...
متن کاملFailure of Anatomic Total Shoulder Arthroplasty with Revision to Another Anatomic Total Shoulder Arthroplasty
Background: While outcomes of primary anatomic total shoulder arthroplasty (aTSA) are generally favorable, resultsafter revision procedures are less reliable. This study examines the functional outcomes, complications, and implantsurvival in patients who underwent revision of aTSA to aTSA.Methods: Patients who underwent revision aTSA were identified from 2008-2015. Demographic, clinical, surgic...
متن کاملComparison of Clinical Results between Patellar Resurfacing and Non-resurfacing in Total Knee Arthroplasty: A Short Term Evaluation
Background: There is no difference in the functional outcomes 6 months after total knee arthroplasty (TKA) for kneeosteoarthritis between patellar resurfacing and non-resurfacing. Thus, we have performed this study to compare theshort-term clinical outcomes of TKA performed with and without the patella resurfacing.Methods: A total of 50 patients with osteoarthritis of the knee (OAK) were random...
متن کامل