Rigid and elastic registration for coronary artery IVUS images.

نویسندگان

  • Zheng Sun
  • Hua Bai
  • Bingru Liu
چکیده

BACKGROUND Intravascular ultrasound (IVUS) has been widely used in diagnosis and interventional treatment of cardiac vessel diseases. The coronary artery IVUS images are usually polluted by motion artifacts caused by cardiac motion, pulsatile blood and catheter twist during continuous pullback acquisition. OBJECTIVE Strategies for rigid and elastic registration of coronary artery IVUS studies are developed to suppress the longitudinal motion and misalignment between successive frames. METHODS Rigid registration is performed by searching for the optimal matching for each frame in other cycles based on the cyclic variation of gray-scale features. The image sequence is gated to properly identify the frames in each cardiac phase. Then, elastic registration between frames is achieved through an optimization algorithm based on thin plate spline (TPS) to correct the misalignment of successive slices. RESULTS Experimental results with in vivo image data shows that the rigid registration performs better than the offline ECG gating. The elastic mapping relation between lumen contours in successive frames is smooth and continuous. CONCLUSION The serrated vessel wall borders in longitudinal cuts are smoothed after rigid registration while image segmentation and feature extraction are required. The point-to-point correspondence between lumen contours detected from two matched frames is obtained with elastic registration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-rigid Registration of Vessel Structures in IVUS Images

We present a registration and retrieval algorithm of medical images. Our algorithm is oriented in a general fashion towards gray level medical images of non-rigid bodies such as coronary vessels, where object shape information provide poor information. We use rich descriptors based on both local and global (contextual) information, and at the same time we use a cooperative-iterative strategy in...

متن کامل

A Feasibility Study of an Intravascular Imaging Antenna to Image Atherosclerotic Plaques in Swine Using 3.0 T MRI

PURPOSE To investigate the feasibility of an intravascular imaging antenna to image abdominal aorta atherosclerotic plaque in swine using 3.0T magnetic resonance imaging (MRI). METHODS Atherosclerotic model was established in 6 swine. After 8 months, swine underwent an MR examination, which was performed using an intravascular imaging guide-wire, and images of the common iliac artery and the ...

متن کامل

Assessment of Inter-Expert Variability and of an Automated Segmentation Method of 40 and 60 MHz IVUS Images of Coronary Arteries

The objectives were to compare the performance of a segmentation algorithm, based on the minimization of an uncertainty function, to delineate contours of external elastic membrane and lumen of human coronary arteries imaged with 40 and 60 MHz IVUS, and to use values of this function to delineate portions of contours with highest uncertainty. For 8 patients, 40 and 60 MHz IVUS coronary data acq...

متن کامل

Feasibility of a novel blood noise reduction algorithm to enhance reproducibility of ultra-high-frequency intravascular ultrasound images.

BACKGROUND Ultra-high-frequency (40- to 50-MHz) intravascular ultrasound (IVUS) improves image quality compared with conventional 20- to 30-MHz IVUS. However, as the frequency of IVUS increases, high-intensity backscatter from blood components may cause visual difficulties in discrimination between the lumen and arterial wall structure. The purpose of this study was to evaluate the effect of a ...

متن کامل

A comparative approach of four different image registration techniques for quantitative assessment of coronary artery calcium lesions using intravascular ultrasound

In IVUS imaging, constant linear velocity and a constant angular velocity of 1800 rev/min causes displacement of the calcium in subsequent image frames. To overcome this error in intravascular ultrasound video, IVUS image frames must be registered prior to the lesion quantification. This paper presents a comprehensive comparison of four registration methods, namely: Rigid, Affine, B-Splines and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Technology and health care : official journal of the European Society for Engineering and Medicine

دوره 24 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2016