Statistical evaluation of the flux cross-calibration of the XMM-Newton EPIC cameras

نویسنده

  • S. Mateos
چکیده

Context. The second XMM-Newton serendipitous source catalogue, 2XMM, provides the ideal data base for performing a statistical evaluation of the flux cross-calibration of the XMM-Newton European Photon Imaging Cameras (EPIC). Aims. We aim to evaluate the status of the relative flux calibration of the EPIC cameras on board the XMM-Newton observatory (MOS1, MOS2, and pn) and investigate the dependence of the calibration on energy (from 0.2 to 12 keV), position of the sources in the field of view of the X-ray detectors, and lifetime of the mission. Methods. We compiled the distribution of flux percentage differences for large samples of ‘good quality’ objects detected with at least two of the EPIC cameras. The mean offset of the fluxes and dispersion of the distributions was then found by Gaussian fitting. Count rate to flux conversion was performed with a fixed spectral model. The impact on the results of varying this model was investigated. Results. Excellent agreement was found between the two EPIC MOS cameras to better than 4% over the entire energy range where the EPIC cameras are best calibrated (0.2-12.0 keV). We found that MOS cameras register 7-9% higher flux than EPIC pn below 4.5 keV and a 10-13% flux excess at the highest energies (& 4.5 keV). No evolution of the flux ratios is seen with time, except at the lowest energies (. 0.5 keV), where we found a strong decrease in the MOS to pn flux ratio with time. This effect is known to be due to a gradually degrading MOS redistribution function. The flux ratios show some dependence on distance from the optical axis in the sense that the MOS to pn flux excess increases with off-axis angle. Furthermore, in the 4.5-12.0 keV band there is a strong dependence of the MOS to pn excess flux on the azimuthal-angle. These results strongly suggest that the calibration of the Reflection Grating Array (RGA) blocking factors is incorrect at high energies. Finally, we recommend ways to improve the calculation of fluxes in future versions of XMM-Newton serendipitous source catalogues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ar X iv : a st ro - p h / 02 03 20 7 v 1 1 3 M ar 2 00 2 1 TIMING WITH THE EPIC PN CAMERA OF XMM - NEWTON

The EPIC pn CCD camera on board of XMM-Newton is designed to perform high throughput imaging and spectroscopy as well as high resolution timing observations in the energy range of 0.1–15keV. A temporal resolution of milliseconds or μ-seconds, depending on the instrument mode and detector, is outstanding for CCD based X-ray cameras. In order to calibrate the different observing modes of the EPIC...

متن کامل

1 Comparison of Xmm-newton Epic, Chandra Acis-s3, Asca Sis and Gis, and Rosat Pspc Results for G21.5-0.9, 1e0102.2-7219, and Ms1054.4-0321

This paper presents a " man on the street " view of the current status of the spectral cross calibration between the XMM-Newton EPIC, Chandra ACIS-S3, ASCA SIS and GIS, and ROSAT PSPC instruments. Using publicly released software for the extraction of spectra and the production of spectral redistribution response matrices and effective areas, the spectral fits of data from three astronomical ob...

متن کامل

In-orbit Vignetting Calibrations of XMM-Newton Telescopes

We describe measurements of the mirror vignetting in the XMM-Newton Observatory made in-orbit, using observations of SNR G21.5-09 and SNR 3C58 with the EPIC imaging cameras. The instrument features that complicate these measurements are briefly described. We show the spatial and energy dependences of measured vignetting, outlining assumptions made in deriving the eventual agreement between simu...

متن کامل

The 2 - 8 keV cosmic X - ray background spectrum as observed with XMM - Newton ⋆

We have measured the spectrum of the Cosmic X-ray Background (CXB) in the 2-8 keV range with the high throughput EPIC/MOS instrument onboard XMM-Newton. A large sample of high galactic latitude observations was used, covering a total solid angle of 5.5 square degrees. Our study is based on a very careful characterization and subtraction of the instrumental background, which is crucial for a rob...

متن کامل

The European Photon Imaging Camera on XMM-Newton: The MOS cameras

The EPIC focal plane imaging spectrometers on XMM-Newton use CCDs to record the images and spectra of celestial X-ray sources focused by the three X-ray mirrors. There is one camera at the focus of each mirror; two of the cameras contain seven MOS CCDs, while the third uses twelve PN CCDs, defining a circular field of view of 30′ diameter in each case. The CCDs were specially developed for EPIC...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009