Fiber-Optic Fabry-Pérot Interferometers for Axial Force Sensing on the Tip of a Needle

نویسندگان

  • Steven Beekmans
  • Thomas Lembrechts
  • John van den Dobbelsteen
  • Dennis van Gerwen
چکیده

A range of complex percutaneous procedures, such as biopsy or regional anesthesia, rely heavily on accurate needle insertion. Small variations in the mechanical properties of the pierced tissue can however cause deviations from the projected needle path and can thus result in inaccurate placement of the needle. Navigation of a rigid needle towards the target tissue is traditionally based on the surgeons capacity to interpret small variations in the needle insertion force. A more accurate measurement of these small force variations enables improvement in needle targeting, can potentially aid in enhancing force feedback in robotic needle placement and can provide valuable information on tissue-tool interaction. In this study we investigated several concepts for the design of a force sensor based on a fiber-optic Fabry-Pérot interferometer to measure needle-tissue interaction forces on the tip of a 18 G needle, where special attention was given to concepts for a sensor with (1), an intrinsic low cross-sensitivity to temperature and (2), elementary design and fabrication. Three concepts, using either a quartz capillary, an Invar capillary or a thin polyimide film as the force sensitive element were prototyped and subjected to both static and dynamic testing. The force transducer based on a quartz capillary presented the lowest cross-sensitivity to temperature ( 12 m N / ∘ C) and good accuracy (maximum measurement error of 65 m N /10 N ) in a measurement of static forces. However, limited strength of the sensor is expected to prevent usage of the quartz capillary in small diameter needles. The concepts for a sensor based on an Invar capillary or a thin polyimide film proved a higher cross-sensitivity to temperature ( 50 m N / ∘ C and 220 m N / ∘ C, respectively) and higher maximum measurement error (350 m N /10 N , 800 m N /10 N ), comparable to those of FBG-based sensors reported in literature, but are likely to be more suitable for integration in very small biopsy needles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Miniature fiber-optic force sensor based on low-coherence Fabry-Pérot interferometry for vitreoretinal microsurgery

During vitreoretinal surgery, the surgeon manipulates retinal tissue with tool-to-tissue interaction forces below the human sensory threshold. A force sensor (FS) integrated with conventional surgical tools may significantly improve the surgery outcome by providing tactile feedback to the surgeon. We designed and built a surgical tool integrated with a miniature FS with an outer diameter smalle...

متن کامل

Application of Thin ZnO ALD Layers in Fiber-Optic Fabry-Pérot Sensing Interferometers

In this paper we investigated the response of a fiber-optic Fabry-Pérot sensing interferometer with thin ZnO layers deposited on the end faces of the optical fibers forming the cavity. Standard telecommunication single-mode optical fiber (SMF-28) segments were used with the thin ZnO layers deposited by Atomic Layer Deposition (ALD). Measurements were performed with the interferometer illuminate...

متن کامل

Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors

Fiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO...

متن کامل

Compressible fiber optic micro-Fabry-Pérot cavity with ultra-high pressure sensitivity.

We propose and demonstrate a pressure sensor based on a micro air bubble at the end facet of a single mode fiber fusion spliced with a silica tube. When immersed into the liquid such as water, the air bubble essentially acts as a Fabry-Pérot interferometer cavity. Such a cavity can be compressed by the environmental pressure and the sensitivity obtained is >1000 nm/kPa, at least one order of ma...

متن کامل

Fabry-Pérot Fiber-Optic Sensors for Physical Parameters Measurement in Challenging Conditions

Optical fiber sensors have unique advantages and distinctive features that make them very attractive for many applications especially those involving challenging conditions where other traditional electrical sensors usually fail. Among the commercially available optical fiber sensors, the Fabry-Pérot sensing technology is probably the most versatile and the most interesting one since a relative...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016