On modeling the tissue response from ultrasonic B-scan images

نویسندگان

  • Udantha Ranjith Abeyratne
  • Athina P. Petropulu
  • John M. Reid
چکیده

The authors model tissue as a collection of point scatterers embedded in a uniform media, and show that the higher-order statistics (HOS) of the scatterer spacing distribution can be estimated from digitized radio frequency (RF) scan line segments and be used in obtaining tissue signatures. The authors assume that RF echoes are non-Gaussian, on the grounds of empirical/theoretical justifications presented in the literature. Based on their model for tissue microstructure, the authors develop schemes for the estimation of reasonable periodicity as well as correlations among nonperiodic scatterers, Using HOS of the scattered signal, the authors define as tissue "color" a quantity that describes the scatterer spatial correlations, show how to evaluate it from the higher-order correlations of the digitized RF scan line segments, and investigate its potential as a tissue signature. The tools employed, i.e., HOS, were chosen as the most appropriate ones because they suppress Gaussian processes, such as the one arising from the diffused scatterers. HOS, unlike second-order statistics, also preserve the Fourier-phase of the signature, the color of the tissue response. Working on simulated and clinical data, the authors show that the proposed periodicity estimation technique is superior to the widely used power spectrum and cepstrum techniques in terms of the accuracy of estimations. The authors also show that even when there is no significant periodicity in data, they are still able to characterize tissues using signatures based on the higher-order cumulant structure of the scatterer spacing distribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

طراحی و ساخت روبشگر فراصوتی جهت تهیه تصاویر روبش B (B-Scan) از قطعات صنعتی

 The results of ultrasonic tests are usually displayed as A-scan signals. In an A-scan signal, reflections of ultrasonic wave form different reflectors are shown as sharp echoes on a time by amplitude display. Interpretation of these echoes can sometimes be quite difficult and usually requires knowledgeable and experienced specialists. There exist other methods of displaying the ultrasonic test...

متن کامل

Three-dimensional simulation of human teeth and its application in dental education and research

Background: A comprehensive database, comprising geometry and properties of human teeth, is needed for dentistry education and dental research. The aim of this study was to create a three-dimensional model of human teeth to improve the dental E-learning and dental research.   Methods: In this study, a cross-section picture of the three-dimensional model of the teeth was used. CT-Scan im...

متن کامل

Assessing the intima-media thickness and Young modulus changes of the common carotid artery in the neck region external radiotherapy based on the processing of ultrasonic images

Since it is too vital to the prevention of carotid disease in the vascular system, it seems necessary to the estimation of the elastic behavior of the carotid artery in head and neck external radiotherapy. In the present study, a total of 24 neck carcinoma patients treated with external radiotherapy had been studied. The carotid mean dose values were determined for each case by contouring the c...

متن کامل

Scanning thermoacoustic tomography in biological tissue.

Microwave-induced thermoacoustic tomography was explored to image biological tissue. Short microwave pulses irradiated tissue to generate acoustic waves by thermoelastic expansion. The microwave-induced thermoacoustic waves were detected with a focused ultrasonic transducer. Each time-domain signal from the ultrasonic transducer represented a one-dimensional image along the acoustic axis of the...

متن کامل

Diagnosis of COVID-19 Disease Using Lung CT-scan Image Processing Techniques

Introduction: Today, several methods are used for detecting COVID-19 such as disease-related clinical symptoms, and more accurate diagnostic methods like lung CT-scan imaging. This study aimed to achieve an accurate diagnostic method for intelligent and automatic diagnosis of COVID-19 using lung CT-scan image processing techniques and utilize the results of this method as an accurate diagnostic...

متن کامل

Diagnosis of COVID-19 Disease Using Lung CT-scan Image Processing Techniques

Introduction: Today, several methods are used for detecting COVID-19 such as disease-related clinical symptoms, and more accurate diagnostic methods like lung CT-scan imaging. This study aimed to achieve an accurate diagnostic method for intelligent and automatic diagnosis of COVID-19 using lung CT-scan image processing techniques and utilize the results of this method as an accurate diagnostic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE transactions on medical imaging

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 1996