Prospective multi-center dosimetry study of low-dose Iodine-125 prostate brachytherapy performed after transurethral resection

نویسندگان

  • Carl Salembier
  • Alex Rijnders
  • Ann Henry
  • Peter Niehoff
  • Frank André Siebert
  • Peter Hoskin
چکیده

PURPOSE To evaluate in a multicenter setting the ability of centers to perform pre-implant permanent prostate brachytherapy planning, fulfilling dosimetric goals and constraints based on the Groupe de Curiethérapie-European Society for Radiotherapy and Oncology guidelines in the setting of implantation after prior prostate transurethral resection (TURP). MATERIAL AND METHODS A reference transrectal ultrasound image set of the prostate gland from a patient who had undergone TURP was used. Contouring of the prostate, clinical target volume and organs at risk was performed by the coordinating center. Goals and constraints regarding the dosimetry were defined. RESULTS Seventeen of twenty-five centers invited to participate were able to import the Digital Imaging and Communications in Medicine-images into their planning computer and plan the implant using the defined guidelines. All centers were able to plan treatment, and achieve the recommended objectives and constraints. However, sector analysis has shown a risk of under-dosage in the anterior part of the prostate. CONCLUSIONS Correct pre-implantation planning with adherence to protocol guidelines and in compliance with defined dosimetric constraints seems feasible in a post-TURP setting, at least on a theoretical basis. A prospective study evaluating the outcome of prostate brachytherapy performed after TURP can therefore be undertaken with an expectation of a correct dosimetry in the multicenter setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First report of transperineal polyethylene glycol hydrogel spacer use to curtail rectal radiation dose after permanent iodine-125 prostate brachytherapy.

PURPOSE To demonstrate the feasibility of transperineal polyethylene glycol (PEG) hydrogel insertion into anterior perirectal fat for reducing rectal radiation dose in patients with suboptimal rectal dosimetry after permanent iodine-125 prostate brachytherapy. METHODS AND MATERIALS Five patients with suboptimal rectal dosimetry after iodine-125 seed brachytherapy implant underwent a single tr...

متن کامل

Clinical implementation of a digital tomosynthesis-based seed reconstruction algorithm for intraoperative postimplant dose evaluation in low dose rate prostate brachytherapy.

PURPOSE The low dose rate brachytherapy procedure would benefit from an intraoperative postimplant dosimetry verification technique to identify possible suboptimal dose coverage and suggest a potential reimplantation. The main objective of this project is to develop an efficient, operator-free, intraoperative seed detection technique using the imaging modalities available in a low dose rate bra...

متن کامل

Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations

Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...

متن کامل

Analysis of the relationship between prescribed dose and dosimetric advantage of real-time intraoperatively built custom-linked seeds in iodine-125 prostate brachytherapy

BACKGROUND The purpose of this study was to investigate the differences in the dosimetric advantage of using intraoperatively built custom-linked (IBCL) seeds between permanent iodine-125 (I-125) seed implantation (PI) alone and PI followed by external-beam radiation therapy (EBRT) for prostate cancer. METHODS We reviewed the records of 62 patients with localized prostate cancer who received ...

متن کامل

Salvage low-dose-rate 125I partial prostate brachytherapy after dose-escalated external beam radiotherapy

PURPOSE To report outcomes on 5 patients treated with salvage partial low-dose-rate (LDR) 125-iodine ((125)I) permanent prostate seed brachytherapy (BT) for biopsy-proven locally persistent prostate cancer, following failure of dose-escalated external beam radiotherapy (EBRT). MATERIAL AND METHODS A retrospective review of the Fox Chase Cancer Center prostate cancer database identified five p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2013