Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery

نویسندگان

  • Elsayed Elmistekawy
  • Yen-Yen Gee
  • Dai Une
  • Matthieu Lemay
  • Anne Stolarik
  • Fraser D. Rubens
چکیده

BACKGROUND Temporary pacemaker wires are placed in the majority of patients after cardiac surgery. There is no information on mechanical factors related to wire removal. METHODS Clinical information related to temporary wire use and removal was prospectively collected from a large cardiac surgical unit over one year. Measurements of maximal tension that nurses and doctors would apply to remove temporary wires was determined using a hand-held portable scale. In a prospective trial, patients (n = 41) had their wires extracted in series to the portable scale to determine the maximal tension required for safe removal. RESULTS Ventricular wires were placed in 86.5 % of patients during the observed year. Pacing facilitated weaning from CPB in over 15 % of patients and pacer dependence was seen in 2.1 %. No patients suffered major complications after wire removal. There was no difference in the tension that physicians or nurses would apply to comfortably extract temporary wires. In the prospective trial, there was no difference in the tension required for removal of atrial or ventricular wires (atrial 18.3 ± 17.9 oz versus 14.5 ± 14.2 oz, p = 0.430). There were no patient factors that correlated with the degree of resistance and there was no significant difference between the tension required to remove wires with (21.0 ± 22.5 oz) or without (14.1 ± 5.1 oz) an atrial button. CONCLUSIONS Temporary epicardial wire removal is innocuous and was not associated with any complications. In some patients tension required for safe removal exceeded 20 ounces. Strategies to standardize wire removal may prevent complications and may minimize unnecessary wire retention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removal of temporary pacemaker after cardiac surgery in infants: A harmless procedure?

External pacemakers (PM) via temporary epicardial leads are routinely applied to infants and children during heart surgery, which usually, after an uneventful post surgical course, can be removed without complications. We report about two infants with complex congenital heart defects after cardiac surgery (arterial switch and Mustard operation for Transposition of the great arteries). Intraoper...

متن کامل

Is there a correlation between late re-exploration after cardiac surgery and removal of epicardial pacemaker wires?

BACKGROUND Re-exploration for bleeding accounts for increased morbidity and mortality after major cardiac operations. The use of temporary epicardial pacemaker wires is a common procedure at many departments. The removal of these wires postoperatively can potentially lead to a serious bleeding necessitating intervention. METHODS From Jan 2011 till Dec 2015 a total of 4244 major cardiac proced...

متن کامل

Temporary epicardial pacing after cardiac surgery: a practical review: part 1: general considerations in the management of epicardial pacing.

Epicardial wires allow temporary pacing after cardiac surgery. Pacing is often the best, and sometimes the only method of treating temporary rhythm disturbances in this context. Temporary epicardial pacing has evolved from simple one-chamber systems to dual chamber, biatrial, and even biventricular systems. The first part of this two-part review provides an overview of the management of tempora...

متن کامل

eComment. Retained temporary epicardial pacing wires in cardiac surgery.

8159.2011.03112.x. [11] Sakellaridis T, Argiriou M, Panagiotakopoulos V, Charitos C. Bilateral sternobronchial fistula after coronary surgery—are retained epicardial pacing wires responsible. J Cardiothorac Surg 2009;4:26. [12] Horng GS, Ashley E, Balsam L, Reitz B, Zamanian RT. Progressive dyspnoea after CABG: complication of retained epicardial pacing wires. Ann Thorac Surg 2008;86:1352–4. [1...

متن کامل

Retained temporary epicardial pacing wires: a rare cause of prosthetic valve endocarditis.

Temporary epicardial pacing wires (TEPWs) are commonly used during cardiac surgery to meet unforeseen complications like heart blocks or asystole. These are generally considered to be safe. The incidence of major complications with their use is low, but could be life threatening. Complications can be divided into those encountered during placement, removal, or retention of temporary epicardial ...