An in Vitro Cost-effective Test Bench for Active Cardiac Implants, Reproducing Human Exposure to Electric Fields 50 Hz
نویسندگان
چکیده
The European Directive 2013/35/UE sets the minimum requirements for the protection of workers exposed to electromagnetic fields and defines workers bearing implants as workers at particular risk. The European standards 50527-1 and 50527-2-1 propose risk assessments methods for these workers, including numerical and/or experimental in-vitro approaches. This study aims to conceive by using both methods, a cost-effective test bench for active cardiac implants in order to reproduce induced phenomena on a cardiac implant inside a human exposed to 50 Hz electric field, representing exposure up to 100 kV/m, which covers occupational exposure.
منابع مشابه
ارزیابی میدانهای الکتریکی و مغناطیسی لامپهای کم مصرف از نوع فلورسنت فشرده از دیدگاه حفاظت پرتوی
The technology used in energy-saving compact fluorescent lamps (CFLs), provides a quarter of the energy consumption of incandescent lamps to produce equivalent light energy while CLFs shelf life is up to ten times of incandescent lamps. So the incandescent lamps in homes and workplaces are replaced with CFLs. Due to the use of ballast in the structure of CFLs, electric and magnetic fields are g...
متن کاملEnvironmental 50Hz Magnetic Fields Can Increase Viability of Human Umbilical Vein Endothelial Cells (HUVEC)
Introduction Over the last decades, considerable levels of electromagnetic fields (EMFs) have been characterized in the living environment. Recent epidemiological studies on occupational and residential exposure to EMF have shown that 50/60 Hz fields, known as extremely low frequencies (ELF), have various biological effects, such as angiogenesis. This study aimed to investigate the effect of en...
متن کاملExperimental and numeric investigation about electromagnetic interference between implantable cardiac pacemaker and magnetic fields at power line frequency.
The present contribute describes the investigation about the implantable pacemaker (PM) immunity against high level magnetic interfering fields at 50 Hz that a pacemaker wearer could find in his working environment. To this purpose, a test bench has been set up based on a Helmholtz coil for producing extremely low frequency (ELF) magnetic fields and a heart simulator rightly fed by electric sig...
متن کاملEffects of RF-EMF Exposure from GSM Mobile Phones on Proliferation Rate of Human Adipose-derived Stem Cells: An In-vitro Study
Background:As the use of mobile phones is increasing, public concern about the harmful effects of radiation emitted by these devices is also growing. In addition, protection questions and biological effects are among growing concerns which have remained largely unanswered. Stem cells are useful models to assess the effects of radiofrequency electromagnetic fields (RF-EMF) on other cell lines. S...
متن کاملThe effect of 17 days exposure to static magnetic fields on the hypothalamic-pituitary-gonadal axis in the male rat
Power stations produce a range of magnetic fields more than 20 mT which are harmful to those working or living around them. Several investigators have reported an increased health risk due to exposure to electric and magnetic fields (EMF) at 50 and 60 Hz. Several studies have been reported especially with increased tumor incidence, effects on reproduction and development, and neural and behavio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017