Comparison of the spatial QRS-T angle derived from digital ECGs recorded using conventional electrode placement with that derived from Mason-Likar electrode position.
نویسندگان
چکیده
BACKGROUND The spatial QRS-T angle is ideally derived from orthogonal leads. We compared the spatial QRS-T angle derived from orthogonal leads reconstructed from digital 12-lead ECGs and from digital Holter ECGs recorded with the Mason-Likar (M-L) electrode positions. METHODS AND RESULTS Orthogonal leads were constructed by the inverse Dower method and used to calculate spatial QRS-T angle by (1) a vector method and (2) a net amplitude method, in 100 volunteers. Spatial QRS-T angles from standard and M-L ECGs differed significantly (57°±18° vs 48°±20° respectively using net amplitude method and 53°±28° vs 48°±23° respectively by vector method; p<0.001). Difference in amplitudes in leads V4-V6 was also observed between Holter and standard ECGs, probably due to a difference in electrical potential at the central terminal. CONCLUSION Mean spatial QRS-T angles derived from standard and M-L lead systems differed by 5°-9°. Though statistically significant, these differences may not be clinically significant.
منابع مشابه
Data Driven Computer Simulation to Analyse an ECG Limb Lead System Used in Connected Health Environments.
BACKGROUND Recently under the Connected Health initiative, researchers and small-medium engineering companies have developed Electrocardiogram (ECG) monitoring devices that incorporate non-standard limb electrode positions, which we have named the Central Einthoven (CE) configuration. OBJECTIVES The main objective of this study is to compare ECG signals recorded from the CE configuration with...
متن کاملQuantative Evaluation of the Efficiency of Facial Bio-potential Signals Based on Forehead Three-Channel Electrode Placement For Facial Gesture Recognition Applicable in a Human-Machine Interface
Introduction: Today, facial bio-potential signals are employed in many human-machine interface applications for enhancing and empowering the rehabilitation process. The main point to achieve that goal is to record appropriate bioelectric signals from the human face by placing and configuring electrodes over it in the right way. In this paper, heuristic geometrical position and configuration of ...
متن کاملComparison of signal quality between EASI and Mason-Likar 12-lead electrocardiograms during physical activity.
BACKGROUND Myoelectric noise and baseline wander, artifacts that appear when patients move during electrocardiographic monitoring, can cause false alarms. This problem can be addressed by using a reduced lead set and placing electrodes on the anterior part of the torso only. The Mason-Likar modification of the standard 12-lead electrocardiogram and the EASI lead system are 2 alternative systems...
متن کاملA comparative study of spatial vectorcardiograms obtained with the equilateral tetrahedron and a corrected system of electrode placement.
Spatial vectorcardiograms of a group of normal young adults, recorded with two systems of electrode placement, have been studied. Those recorded with the equilateral tetrahedron as the reference system were similar to records previously described and had QRS-loops of two configurations. Those recorded with a method of lead placement designed to reduce the errors inherent in the commonly used re...
متن کاملModified electrode placement must be recorded when performing 12-lead electrocardiograms.
BACKGROUND Local observation has suggested that placing limb leads on the torso when recording the standard 12-lead resting electrocardiogram (ECG) has become commonplace. This non-standard modification has the important advantages of ease and speed of application, and in an emergency may be applied with minimal undressing. Limb movement artefact is also reduced. It is believed that ECGs obtain...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of electrocardiology
دوره 49 5 شماره
صفحات -
تاریخ انتشار 2016