Achievable resolution from images of biological specimens acquired from a 4k x 4k CCD camera in a 300-kV electron cryomicroscope.
نویسندگان
چکیده
Bacteriorhodopsin and epsilon 15 bacteriophage were used as biological test specimens to evaluate the potential structural resolution with images captured from a 4k x 4k charge-coupled device (CCD) camera in a 300-kV electron cryomicroscope. The phase residuals computed from the bacteriorhodopsin CCD images taken at 84,000x effective magnification averaged 15.7 degrees out to 5.8-A resolution relative to Henderson's published values. Using a single-particle reconstruction technique, we obtained an 8.2-A icosahedral structure of epsilon 15 bacteriophage with the CCD images collected at an effective magnification of 56,000x. These results demonstrate that it is feasible to retrieve biological structures to a resolution close to 2/3 of the Nyquist frequency from the CCD images recorded in a 300-kV electron cryomicroscope at a moderately high but practically acceptable microscope magnification.
منابع مشابه
4.6 Å Cryo-EM reconstruction of tobacco mosaic virus from images recorded at 300 keV on a 4k × 4k CCD camera
Tobacco mosaic virus (TMV) is a plant virus with a highly ordered organisation and has been described in three different structural states: As stacked disks without RNA (X-ray crystallography), as a helical form with RNA (X-ray fibre diffraction) and as a second distinct helical form with RNA (cryo-EM). Here we present a structural analysis of TMV as a test object to assess the quality of cryo-...
متن کاملA 9 A single particle reconstruction from CCD captured images on a 200 kV electron cryomicroscope
Sub-nanometer resolution structure determination is becoming a common practice in electron cryomicroscopy of macromolecular assemblies. The data for these studies have until now been collected on photographic film. Using cytoplasmic polyhedrosis virus (CPV), a previously determined structure, as a test specimen, we show the feasibility of obtaining a 9 A structure from images acquired from a 4 ...
متن کامل4K Video-Laryngoscopy and Video-Stroboscopy: Preliminary Findings.
INTRODUCTION 4K video is a new format. At 3840 × 2160 resolution, it has 4 times the resolution of standard 1080 high definition (HD) video. Magnification can be done without loss of resolution. This study uses 4K video for video-stroboscopy. MATERIAL AND METHOD Forty-six patients were examined by conventional video-stroboscopy (digital 3 chip CCD) and compared with 4K video-stroboscopy. The ...
متن کاملOff-Axial Aberration Correction using a B-COR for Lorentz and HREM Modes
A dedicated Hitachi HF3300C microscope, “I2TEM”, has recently been installed in CEMES. This microscope has been specially designed to carry on electron interferometry and in-situ TEM experiments. I2TEM is a 300 kV cold FEG microscope fitted with a multibrism set-up, two stages capability, a GIF quantum ER, a 4k X 4k camera and a Cs-corrector “B-COR” from CEOS. The first stage location within th...
متن کاملAirborne Testing of the Dss: Test Results and Analysis
In this paper, the Digital Sensor System (DSS) test results and analysis are presented. The DSS is a fully integrated fully digital ruggedized system for airborne image acquisition, georeferencing, and map production. The DSS consists of a 4K x 4K digital camera, a GPS-aided INS direct georeferencing system, and a flight management system. The DSS software suite interfaces seamlessly with comme...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of structural biology
دوره 163 1 شماره
صفحات -
تاریخ انتشار 2008