A study of the effects of ranolazine using automated quantitative analysis of serial myocardial perfusion images.

نویسندگان

  • Rajesh Venkataraman
  • Luiz Belardinelli
  • Brent Blackburn
  • Jaekyeong Heo
  • Ami E Iskandrian
چکیده

OBJECTIVES This study examined the hypothesis that the improvement in myocardial blood flow (MBF) with ranolazine therapy could be detected by serial automated quantitative myocardial perfusion imaging (MPI) in patients with coronary artery disease (CAD) and myocardial ischemia. BACKGROUND Myocardial ischemia enhances late sodium current, which then causes cellular calcium overload leading to mechanical left ventricular dysfunction and arrhythmias. Ranolazine inhibits late sodium current and improves diastolic tension and MBF in the animal model. METHODS In this open-label, nonrandomized pilot study, we recruited 20 patients with known or a high probability of CAD and who had reversible perfusion defects on exercise treadmill gated single-photon emission computed tomography MPI while receiving conventional antianginal therapy. Ranolazine (up to 1,000 mg twice daily) was added to baseline therapy and a repeat treadmill MPI was obtained after 4 weeks. The extent and severity of total and reversible left ventricular perfusion abnormality (based on polar maps and a 17-segment model) were determined quantitatively using automated methods. RESULTS We screened 100 patients for 27 potential candidates; 5 declined and 2 did not complete the follow-up study. The mean age of the remaining 20 patients was 64 +/- 9 years; 30% were women and 50% had diabetes mellitus. The exercise time increased (425 +/- 105 s vs. 393 +/- 116 s, p = 0.017), and angina improved in 15 (75%) patients after ranolazine treatment. In the entire cohort, summed stress scores (10 +/- 7 vs. 13 +/- 8, p = 0.04) and summed difference scores (4.7 +/- 4 vs. 7.4 +/- 5, p = 0.0037) decreased at follow-up. An improvement in perfusion pattern and severity was noted in 14 (70%) patients. In these patients, the polar maps showed a decrease in total abnormality from 26 +/- 17% to 19 +/- 15% and a decrease in the reversible abnormality from 16 +/- 10% to 8 +/- 6% (all p values <0.05). CONCLUSIONS In this preliminary hypothesis-driven study, short-term ranolazine therapy was shown to improve myocardial perfusion and decrease the ischemic burden in patients with CAD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Serial Myocardial Imaging after a Single Dose of Thallium-201

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 2 11  شماره 

صفحات  -

تاریخ انتشار 2009