Absolute activity quantitation in simultaneous 123I/99mTc brain SPECT.

نویسندگان

  • G El Fakhri
  • S C Moore
  • P Maksud
  • A Aurengo
  • M F Kijewski
چکیده

UNLABELLED Dual-isotope imaging can allow simultaneous assessment of brain perfusion using a 99mTc-labeled tracer and neurotransmission using an 123I-labeled tracer. However, the images are affected by scatter, cross talk, attenuation, distance-dependent collimator response (DCR), and partial-volume effect. We determined the accuracy and precision of activity quantitation in simulated normal and pathologic studies of simultaneous 123I/99mTc brain SPECT when compensating for all degrading phenomena. METHODS Monte Carlo simulations were performed using the Zubal brain phantom. Contamination caused by high-energy 123I decay photons was incorporated. Twenty-four 99mTc and 123I activity distributions were simulated on the basis of normal and pathologic patient activity distributions. Cross talk and scatter were corrected using a new method based on a multilayer perceptron artificial neural network (ANN), as well as by the asymmetric window (AW) approach; for comparison, unscattered (U) photons of 99mTc and 123I were recorded. Nonuniform attenuation and DCR were modeled in an iterative ordered-subset expectation maximization (OSEM) algorithm. Mean percentage biases and SDs over the 12 normal and 12 pathologic simulated studies were computed for each structure with respect to the known activity distributions. RESULTS For 123I, AW + OSEM yielded a bias of 7% in the cerebellum, 21% in the frontal cortex, and 36% in the corpus callosum in the simulated normal population. The bias was increased significantly in the striata of simulated pathologic studies (P < 0.05). The bias associated with ANN was significantly lower (<9% in these brain structures, P < 0.05). For 99mTc with AW + OSEM, the bias was 60% in the corpus callosum, 36% in the striata, and 18%-22% in the cortical lobes in the simulated normal population. This bias was <11% in all brain structures with ANN. In the simulated pathologic population, the bias associated with AW increased significantly in the cortical lobes to 55% (P < 0.05), although it did not change significantly with ANN. CONCLUSION The accuracy and variability over simulated normal and pathologic studies of both 99mTc and 123I activity estimates were very close with ANN to those obtained with U + OSEM. ANN + OSEM is a promising approach for absolute activity quantitation in simultaneous 99mTc/123I SPECT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual radioisotopes simultaneous SPECT of 99mTc-tetrofosmin and 123I-BMIPP using a semiconductor detector.

Objective(s): The energy resolution of a cadmium-zinc-telluride (CZT) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional Anger type detector which is 10%. Also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. In this study, we used a semiconductor detector and examined the ef...

متن کامل

Scatter correction based on an artificial neural network for 99mTc and 123I dual-isotope SPECT in myocardial and brain imaging.

UNLABELLED The aim of this study was to elucidate the clinical usefulness of scatter correction with an artificial neural network (ANN) in 99mTc and 123I dual-isotope SPECT. METHODS Two algorithms for ANN scatter correction were tested: ANN-10 and ANN-3 employing 10 and 3 energy windows for data acquisition, respectively. Three patients underwent myocardial or brain SPECT with one of the foll...

متن کامل

Sequential and simultaneous dual-isotope brain SPECT: comparison with PET for estimation and discrimination tasks in early Parkinson disease.

Parkinson disease (PD) is the second most frequently occurring cerebral degenerative disease, after Alzheimer disease. Treatments are available, but their efficacy is diminished unless they are administered in the early stages. Therefore, early identification of PD is crucial. In addition to providing perfectly registered studies, simultaneous 99mTc/123I imaging makes possible the assessment of...

متن کامل

99mTc-Sestamibi/123I Subtraction SPECT/CT in Parathyroid Scintigraphy: Is Additional Pinhole Imaging Useful?

Objectives This retrospective study evaluated whether the use of additional anterior 99mTc-sestamibi/123I pinhole imaging improves the outcome of 99mTc-sestamibi/123I subtraction SPECT/CT in parathyroid scintigraphy (PS). Materials and Methods PS using simultaneous dual-isotope subtraction methods and an acquisition protocol combining SPECT/CT and planar pinhole imaging was performed for 175 ...

متن کامل

Generalized five-dimensional dynamic and spectral factor analysis.

We have generalized the spectral factor analysis and the factor analysis of dynamic sequences (FADS) in SPECT imaging to a five-dimensional general factor analysis model (5D-GFA), where the five dimensions are the three spatial dimensions, photon energy, and time. The generalized model yields a significant advantage in terms of the ratio of the number of equations to that of unknowns in the fac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 2001