An Array RF Coil for Rabbit Thoracic Arteries Imaging at 200MHz

نویسنده

  • R. P. Joensuu
چکیده

Introduction Parallel imaging is becoming standard in clinical systems but it still relatively uncommon in animal MRI studies. Most of the animal coil array designs have so focused on mouse and rat imaging applications, however larger animal models such as rabbits are also widely used in research, for example in vessel wall studies. The purpose of this work was to design a 4-channel array coil for rabbit’s thoracic arteries imaging at 4.7T.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

Design and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system.

PURPOSE Magnetic resonance imaging (MRI) of rodents can be expected to be a growing application, particularly when translatory imaging research "from mouse to man" is envisioned. 7 T high-field human whole-body MR systems provide a powerful platform for high-resolution small animal imaging. For achieving adequate spatial resolution, dedicated radiofrequency coils have to be designed to provide ...

متن کامل

Numerical Evaluation of an 8-element Phased Array Torso Coil for Magnetic Resonance Imaging

Recently, parallel imaging using multiple RF coils has excited great interest in magnetic resonance imaging (MRI). To help the design of some novel flexible array coils for the human torso, we theoretically investigate the RF field of an 8-element array coil loaded with an anatomically accurate model of the human torso. The RF behaviour is predicted based on a hybrid FDTD/MoM approach. The prim...

متن کامل

Ophthalmic magnetic resonance imaging at 7 T using a 6-channel transceiver radiofrequency coil array in healthy subjects and patients with intraocular masses.

OBJECTIVES This study was designed to examine the feasibility of ophthalmic magnetic resonance imaging (MRI) at 7 T using a local 6-channel transmit/receive radiofrequency (RF) coil array in healthy volunteers and patients with intraocular masses. MATERIALS AND METHODS A novel 6-element transceiver RF coil array that makes uses of loop elements and that is customized for eye imaging at 7 T is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008