Mobile-bearing knee replacement: concepts and results.
نویسندگان
چکیده
In summary, if TKRs are to be performed in patients who are younger and more active than those who had the initial procedures in the 1970s and 1980s, better wear performance is imperative for long-term durability, especially if surgeons continue to consider the versatility associated with modular knee-replacement systems to be a necessity. At least with some designs, including the Oxford knee and the LCS knee, the results after a minimum follow-up of 10 years are comparable with the best results after arthroplasty with fixed-bearing designs in terms of wear, loosening, and osteolysis (Table 7). As with fixed-bearing designs, there are additional challenges in terms of optimizing bearing-surface conformity and improving kinematics. Improvements in future designs of mobile-bearing total knee replacements should include better control of bearing mobility patterns to reduce the prevalence of the abnormal kinematic motions that have been observed in fluoroscopic evaluations.
منابع مشابه
Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience
Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedialosteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement overphase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rateand improved component alignment. We report the results...
متن کاملSimultaneous mobile- and fixed-bearing total knee replacement in the same patients. A prospective comparison of mid-term outcomes using a similar design of prosthesis.
We conducted a randomised prospective study to evaluate the clinical and radiological results of a mobile- and fixed-bearing total knee replacement of similar design in 174 patients who had bilateral simultaneous knee replacement. The mean follow-up was for 5.6 years (5.2 to 6.1). The total knee score, pain score, functional score and range of movement were not statistically different (p > 0.05...
متن کاملOne Year After Navigated Total Knee Replacement, No Clinically Relevant Difference Found Between Fixed Bearing and Mobile Bearing Knee Replacement in a Double-Blind Randomized Controlled Trial
BACKGROUND The mobile bearing designs have not yet been shown to improve clinical outcome of total knee arthroplasty (TKA). In this prospective randomized study, we compared the short-term clinical results of a mobile bearing implant with those of the fixed bearing version of the same implant. METHODS We randomized 100 knees into two double-blind groups who received either the fixed (FB, 52 k...
متن کاملMedium-term outcome of titanium nitride, mobile bearing total knee replacement.
This retrospective study examined the medium term outcome of 305 Titanium Nitride (TiN) Mobile bearing total knee. At ten years after the start of the study, there was a significant improvement (p < 0.0001) in the post-operative knee scores. The ten year survival with revision for any reason as the end point was 95.1% (95% CI 92.4 to 97.8). The ten year survival rate with revision for aseptic l...
متن کاملLow-Contact-Stress Knee Arthroplasty: Past History or Ahead of Time?
Low-contact-stress mobile-bearing (MB) total knee arthroplasty (TKA) can rely on a long history. Its concept comprises a combination of high condylar congruency and compensatory bearing rotation to promote load sharing. However, other MB designs have become available, and critical points have been raised about the benefit of MB in general. Although there is kinematic and kinetic support for the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Instructional course lectures
دوره 50 شماره