Quality Power Provider Operating in Distorted and Unbalanced Three- phase Supply Condition
نویسندگان
چکیده
The quality of voltage and current delivered by the power utilities has become a major concern of the modern industries. The common power quality problems are voltage sag, voltage imbalance, transients, interruptions and harmonics. The two major power quality disturbances are voltage sag and harmonic distortion. In this paper, a Quality Power Provider (QPP) based on voltage source inverter is modeled by simulation to compensate the power quality disturbances such as voltage sag and voltage harmonics in the distorted and unbalanced supply condition. The phase locked loop (PLL) is an important control unit of the QPP control scheme. To obtain accurate phase information and frequency of the input supply, the dqPLL method has been proposed. The proposed structure uses the coordinate transformation of 3-phase voltages form ab-c to d-q and generate two voltage variables direct-axis (Vd) and quadrature-axis (Vq) as dc variables which are easy to apply in filtering techniques. The d-q PLL technique maintains the output signal by tracking the phase of the supply voltage and by controlling the phase shift Vq to zero. Hence in system steady state, the absolute value of Vd equals the supply voltage. The QPP has been modeled and simulation is done using PSCAD software. The control scheme is able to mitigate voltage sag and voltage harmonics, fast and efficiently with low total harmonics distortion (THD). With the improvised scheme, QPP is able to achieve an improved performance, thus increasing the power rating and minimum energy injection. In addition a zero-sequence component remover has been included to minimize the THD level. The proposed QPP has enhanced the quality of power supply at the sensitive load end.
منابع مشابه
The New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace
The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...
متن کاملThe New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace
The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...
متن کاملA Method for Quality Power Provider to Operate in Distorted Supply Condition
Power Quality is a major concern within power industry and consumers. Poor quality of supply will affect the performance of customer equipment such as computers, microprocessors, adjustable speed drives, power electronic controllers, life saving equipment in hospitals, etc. and result in heavy financial losses to customers due to loss of production or breakdown in industries or loss of life in ...
متن کاملImplementation of Neural network based I cos φ Controller for DSTATCOM in Three Phase Four Wire Distribution System under Varying Source and Load Conditions for Power Quality Improvement
The application of power semiconductor devices in the area of power electronics and power system are the key factors which kindle the power quality problems particularly the harmonics, burden of reactive power and neutral current due to unbalance. The above citied power quality problems are predominant due to wide usage of 1-φ / 3-φ , linear and nonlinear loads which are fed from three phase fo...
متن کاملLow Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage
In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...
متن کامل