Clinical Tests Combined with Color Doppler Versus Color Doppler Alone in Identifying Incompetent Perforator Veins of the Lower Limb: A Prospective Analytical Study

نویسندگان

  • Sathasivam Sureshkumar
  • Narayan Vignesh
  • J Venkatachalam
  • Chellappa Vijayakumar
  • Sundaramurthi Sudharsanan
چکیده

Background The color Doppler, a better investigation to identify the perforators objectively has replaced the clinical examination for the same. However, this has led to a significant number of negative explorations and cosmetic disfigurement. Objective To compare the efficacy of the clinical tests combined with the color Doppler versus color Doppler alone to identify the perforator incompetence during the surgery for primary varicose veins of the lower limb. Methods This was a prospective analytical study, including 61 lower limb varicose vein patients who belonged to the Clinical-Etiology-Anatomy-Pathophysiology (CEAP) class four-six, planned for the surgical treatment for perforator incompetence, excluding those requiring additional vascular or nonvascular procedure, recurrent varicose veins and those who had injection sclerotherapy prior to the surgery. The clinical tests, including Trendelenburg's test, multiple tourniquet tests and, the Fegan's tests were performed and incompetent perforators were marked on a template as 'C' to indicate the clinically positive perforator incompetence. The patients were then examined with the color Doppler ultrasound and the pathological incompetent perforators were marked as 'D'. The surgical management of the perforator incompetence was done by stab ligation. The incision was made in the color Doppler 'D' marked sites as it has been the standard protocol. The number of incompetent perforators identified during the surgical exploration were categorized as 'D' positive or 'C' and 'D' positive and were recorded in the specified proforma. Results It was found that the mean number of the perforator incompetence identified by the color Doppler alone was 8.2 whereas during the surgery, only a mean of six perforators was identified, leading to 20 unnecessary explorations per 10 patients (8.2 vs. 6; mean difference 2.229; P <0.001). The mean number of the perforator incompetence identified by the color Doppler combined with the clinical tests was 4.5 and during the surgery, a mean of four perforators was identified (4.5 vs. 4; mean difference 0.377; P <0.001). The color Doppler combined with the clinical examination lead to only four unnecessary explorations per 10 patients. Conclusion A combination of both the clinical tests and the color Doppler ultrasound has a higher accuracy in detecting perforator incompetence and can reduce the number of negative explorations by the rate of 16 unnecessary explorations per 10 patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional color Doppler ultrasonography of the kidney vasculature in normal dogs

Three-dimensional color Doppler ultrasonography is a new technique to evaluate the pattern of blood vessels. This study was performed to assess the feasibility of this method in evaluation of kidney vasculature pattern in dogs. In this paper, visualization of the Renal, Interlobar, Arcuate, and interlobular arteries and veins using 3D color Doppler ultrasonography in dogs is shown and the techn...

متن کامل

Perforator Flaps for Reconstruction of Lower Limb Defects

BACKGROUND Reconstruction of soft tissue defects in the lower third of the leg remains challenging. Anatomical constraints limit the local options available for complex defects especially lower third of leg. Local flaps based on perforator vessels are raising interest in reconstructive surgery of the limbs. We present our experience with perforator flaps for reconstruction of soft tissue def...

متن کامل

The Prevalence and Risk Factors of Venous Thrombosis among Hospitalized Patients: Are Wells Criteria Considered by Primary Care Physicians?

Background: Deep vein thrombosis (DVT) is one of the main causes of hospital mortality which can easily be prevented. Three para clinical methods are used to confirm the diagnosis of DVT, which include D-dimer test, venous color Doppler ultrasonography and venography. This study has focused on the prevalence of confirmed DVT in lower limbs based on venous color Doppler ultrason...

متن کامل

Three-Dimensional Color Doppler Ultrasonography Study of Normal Liver Vascular Pattern in Dog

Objective- To create three-dimensional model of the dog's liver vessels by using threedimensionalcolor Doppler ultrasonography which can be used for surgery planning,tumor detecting, transplantation, and other diagnostic or treatment project.Design- Descriptive studyAnimals- 6 mixed breed dog, 1.6-1.7 years old, 18-20 kg weightProcedures- The liver was found by two-dimensional scan initially th...

متن کامل

Association of venous volume and diameter of incompetent perforator veins in the lower limb--implications for perforator vein surgery.

PURPOSE To define the association between venous volume as measured with air-plethysmography and the duplex ultrasound measured diameter of incompetent perforator of the lower limb. PATIENTS AND METHODS Thirty-six patients with chronic venous disease were investigated with air-plethysmography and duplex ultrasound. Venous volume and venous filling time was measured. Venous filling index was c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2018