Linear and Non - linear modeling of a dose - response curve using SAS

نویسنده

  • Eli Lilly
چکیده

In clinical trials response variables are measured at different times and doses. This paper explores methods to determine the dose that optimizes the response based on multiple responses and doses. Linear dose-response modeling can be performed using repeated measures analysis (using PROC MIXED) for change in response (Y) using dose (X) as a continuous explanatory variable with time, dose, and time-by-dose interaction as fixed effects. The error structure to model the correlation between the repeated measures needs to be determined e.g. using the Akaike information criteria. To compare the responses at each dose, additional analyses using dose as a classification variable can be performed and pairwise comparisons can be obtained. Non-linear dose response modeling can be performed using continuous dose, X (using PROC NLIN) with the following model: Percent change in Y= b0 + (X . b1)/(X + b2 ) + error, where b0 is the response at dose = 0, b1 is the optimum % change in Y compared to dose = 0 and b2 is the dose at 50% of b1. A fixed value of γ can be chosen based on minimum residual sum of squares. Predicted values are calculated and plotted against the observed % change in Y for all doses. Additionally PROC CAPABILITY can be used to determine the best fitted distribution of Y among the exponential family and plotted for different doses. These methods were applied to analyze the pooled data from two clinical trials. Various determination of the “optimal dose” was considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams

Background: The purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. Materials and Methods: Human peripheral blood lymphocytes were irradiated using proton beams (LET: 34.6 keV μm−1), and the chromosome aberrations induced were analyzed using cytokinesis-blocked (CB) micronucleus (MN) assay. To determine th...

متن کامل

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

متن کامل

Determination of dose-response relationship in cultured human lymphocytes for biological dosimetry

Background: Lymphocyte-dicentric assay is the most generally accepted method for biological dosimetry of overexposed individuals. In this study, the frequency of unstable chromosome aberration in blood lymphocytes was used to estimate radiation dose received by individuals. Evaluation of dose using a calibration curve produced elsewhere may have a significant uncertainty therefore, experiments ...

متن کامل

Biological Dose Assessment by Chemical Induction of Premature Chromosome Condensation

Dose assessment of radiation victims is a key element in medical management of radiation accidents. At high radiation doses (> 6 Gy), dicentric assay lose its efficiency and premature chromosome condensation (PCC) assay was proposed to overcome the restrictions of dicentric assay. It was shown that PCC ring is more suitable and simpler than dicentric for biodosimetry in high radiation doses. In...

متن کامل

Non-linear phenomena in biological findings of the residents of high background radiation areas of Ramsar

Some Areas of Ramsar, a city in northern Iran are among the world’s wellknown inhabited areas with highest levels of natural radiation. Annual exposure levels in these areas are up to 260 mGy y‐1 and the mean exposure rate is about 10 mGy y‐1 for a population of about 2000 residents. If elevated levels of natural radiation as high as a few hundred mSv per year is detrimental to health and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000