Simultaneous quadruple-label fluorometric immunoassay of thyroid-stimulating hormone, 17 alpha-hydroxyprogesterone, immunoreactive trypsin, and creatine kinase MM isoenzyme in dried blood spots.

نویسندگان

  • Y Y Xu
  • K Pettersson
  • K Blomberg
  • I Hemmilä
  • H Mikola
  • T Lövgren
چکیده

We describe a quadruple-label fluorometric immunoassay for simultaneously measuring four analytes: thyroid-stimulating hormone (TSH), 17 alpha-hydroxyprogesterone (17 alpha-OHP), immunoreactive trypsin (IRT), and creatine kinase MM (CK-MM). The assay is based on immunoreagents labeled with four different lanthanide ions (Eu3+, Tb3+, Sm3+, and Dy3+), on dissociative fluorescence enhancement applying the principle of co-fluorescence, and on time-resolved fluorometry. The monoclonal anti-alpha-TSH and anti-IRT antibodies and the polyclonal anti-CK-MM antibody were labeled with Eu3+, Sm3+, and Dy3+, respectively; 17 alpha-OHP was labeled with Tb3+. The assay was performed in microtitration strip wells coated with a mixture of monoclonal antibodies against beta-TSH, IRT, and CK-MM and a polyclonal goat anti-rabbit IgG for capture of the rabbit anti-17 alpha-OHP antibodies. After completion of the immunoreactions, the bound fractions of the lanthanides were dissociated into the co-fluorescence enhancement solution, creating highly fluorescent chelates. The four lanthanide-specific signals were subsequently measured in a time-resolved fluorometer. The detection limits of the assay were 0.1 mIU/L for TSH, 2 nmol/L for 17 alpha-OHP, 2 micrograms/L for IRT, and 4 U/L for CK-MM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EDTA in dried blood spots leads to false results in neonatal endocrinologic screening.

BACKGROUND Blood samples for neonatal screening for inborn errors of metabolism are collected and shipped on standardized filter paper cards. Occasionally these samples are contaminated with EDTA, which is often used for anticoagulation. EDTA may interfere with newborn screening tests based on lanthanide fluorescence and thus lead to false-negative or false-positive results. METHODS We used t...

متن کامل

A Simple Method to Overcome the “Floating Disc Problem” Using the GALT-Assay on the PerkinElmer GSP—Remeasurement on a Stand Alone Plate Fluorimeter

The Perkin Elmer Genetic Screening Processor (GSP)TM is a fully automated system for the processing of immunoassays for thyroid stimulating hormone (TSH), 17-hydroxyprogesterone (17-OHP), immuno reactive trypsin (IRT), biotinidase, and total T4, as well as enzymatic assays for total galactose and galactose-1-phosphate uridyltransferase (GALT) from dried blood spots (DBS). The system however, ha...

متن کامل

Direct solid-phase time-resolved fluoroimmunoassay of 17 alpha-hydroxyprogesterone in serum and dried blood spots on filter paper.

We describe a direct, solid-phase time-resolved fluoroimmunoassay (TRFIA) for measuring 17 alpha-hydroxyprogesterone (17OHP) in serum and blood spots on filter paper. We used 17OHP-3-carboxymethyloxime (17OHP3CMO) coupled to polylysine as the label, which enabled incorporation of up to 34 atoms of europium per molecule of 17OHP, for a very high specific activity. The assay is based on competiti...

متن کامل

Hormonal responses to synthetic luteinizing hormone and follicle stimulating hormone-releasing hormone in man.

The effects of the gonadotrophin-releasing hormone, synthetic decapeptide luteinizing hormone/follicle stimulating hormone-releasing hormone (LH/FSH-RH), have been studied in 18 normal men and five women in the follicular phase of their menstrual cycle. Rapid and dose-dependent (25 to 100 mug) increases in serum immunoreactive LH were seen, which reached a peak 20 to 30 minutes after a rapid in...

متن کامل

Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays.

We investigated the use of serum samples from BD Vacutainer rapid serum tubes (RSTs; BD, Franklin Lakes, NJ) to reduce undetermined interferences contributing to false-positive immunoassay results in heparin plasma samples. Patients being evaluated for suspected myocardial infarction had specimens drawn into an RST in addition to the standard lithium-heparin plasma separator tube (PST). We meas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 10  شماره 

صفحات  -

تاریخ انتشار 1992