The use of a T-plate as "spring plates" for small comminuted posterior wall fragments.

نویسندگان

  • Bruce H Ziran
  • Jill E Little
  • Ramsey C Kinney
چکیده

In the treatment of posterior wall fractures of the acetabulum, a modified distal radius T-plate can be substituted for one third tubular spring plates for fixation of thin, small, or comminuted posterior wall fragments. This technique is described as well as a case series of 33 patients with various posterior wall acetabular fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-level reconstruction of comminuted posterior-wall fractures of the acetabulum.

Our aim was to evaluate the efficacy of a two-level reconstruction technique using subchondral miniscrews for the stabilisation of comminuted posterior-wall marginal acetabular fragments before applying lag screws and a buttress plate to the main overlying posterior fragment. Between 1995 and 2003, 29 consecutive patients with acute comminuted displaced posterior-wall fractures of the acetabulu...

متن کامل

Frequency Aanalysis of Annular Plates Having a Small Core and Guided Edges at Both Inner and Outer Boundaries

This paper deals with frequency analysis of annular plates having a small core and guided edges at both inner and outer boundaries. Using classical plate theory the governing differential equation of motion for the annular plate having a small core is derived and solved for the case of plate being guided at inner and outer edge boundaries. The fundamental frequencies for the first six modes of ...

متن کامل

Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability.

BACKGROUND Volar plate fixation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted extra-articular distal radial fractures. The purpose of the present study was to compare the relative stability of five distal radial plates (four volar and one dorsal), all of which are commonly used for the treatme...

متن کامل

Comminuted olecranon fractures: a comparison of plating methods.

The relative strength of posterior plating and dual medial-lateral plating for comminuted olecranon fractures has not been evaluated. Fifteen male cadaveric elbows with simulated highly comminuted olecranon fractures were tested to failure via cantilever bending. The strength of dual medial-lateral plates and a single posterior plate with and without an intramedullary screw was evaluated. The m...

متن کامل

Effect of Vertical Plates on Reducing Vortex Using Experimental Data

This paper is about experimental results for partial reduction of vortex at vertical pipe intakes. One of the easiest and practical ways of reducing vortex effect is to use anti-vortex plates or baffles. These plates can be used to avoid the vortex completely or partially. This paper will concentrate on the latter case. Rectangular plates with different dimensions have been placed at different ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic trauma

دوره 25 9  شماره 

صفحات  -

تاریخ انتشار 2011