Detection of intracranial atherosclerotic steno-occlusive disease with 3D time-of-flight magnetic resonance angiography with sensitivity encoding at 3T.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The spatial resolution of 3D time-of-flight MR angiography (TOF-MRA) can be improved within a reasonable examination time by combining 3T and sensitivity encoding technique. We evaluated the diagnostic performance of high-resolution 3D TOF-MRA at 3T in patients with suspected atherosclerotic steno-occlusive disease of the intracranial arteries. MATERIALS AND METHODS We assessed 160 arteries in 39 patients: 68 distal internal carotid arteries, 68 middle cerebral arteries, and 24 vertebrobasilar arteries. The measured voxel size of 3D TOF-MRA was 0.28 x 0.56 x 1.2 mm(3). Steno-occlusive disease was assessed independently by 2 observers using conventional angiography as the reference standard. RESULTS According to observers 1 and 2, respectively, 3D TOF-MRA at 3T had a sensitivity of 78%/85% (21/27, 23/27), a specificity of 95%/95% (126/133, 127/133), a positive predictive value of 75%/79% (21/28, 23/29), and a negative predictive value of 95%/97% (126/132, 127/131), using a 50%-99% threshold of diameter stenosis. For detection of complete occlusion, according to observers 1 and 2, respectively, 3D TOF-MRA at 3T had a sensitivity of 100% (13/13), a specificity of 99% (145/147), a positive predictive value of 87% (13/15), and a negative predictive value of 100% (145/145). Interobserver agreement of 3D TOF-MRA was excellent (kappa = 0.81). CONCLUSION High-resolution 3D TOF-MRA with sensitivity encoding at 3T can be used as a reliable diagnostic tool for the detection of clinically significant steno-occlusive disease of major intracranial arteries.
منابع مشابه
Noninvasive detection of steno-occlusive disease of the supra-aortic arteries with three-dimensional contrast-enhanced magnetic resonance angiography: a prospective, intra-individual comparative analysis with digital subtraction angiography.
BACKGROUND AND PURPOSE Concomitant disease of the supra-aortic arteries can influence the outcome of surgical treatment of carotid artery stenosis. However, sensitivity and specificity data of noninvasive contrast-enhanced 3-dimensional (3D) magnetic resonance angiography (CE MRA) for the detection of steno-occlusive disease of the entire supra-aortic arteries including the circle of Willis rem...
متن کاملIntracranial steno-occlusive arterial disease and its associations in Egyptian ischemic stroke patients.
BACKGROUND AND PURPOSE Intracranial arterial steno-occlusive disease is prevalent among non-white populations. We explored whether a similar pattern exists in Egyptians and assessed its clinical-radiological associations. METHODS Consecutive acute ischemic stroke patients were recruited for 6 months and had magnetic resonance imaging/magnetic resonance angiography of brain within 2 days of th...
متن کاملDiagnosis of unruptured intracranial aneurysms: 3T MR angiography versus 64-channel multi-detector row CT angiography.
BACKGROUND AND PURPOSE We compared 3-dimensional time-of-flight magnetic resonance angiography (3D TOF MRA) using a 3-tesla (T) MR unit with 64-channel multi-detector row computed tomographic angiography (64-MDCTA) for detection and characterization of angiographically proven unruptured intracranial aneurysms. METHODS Thirty-eight patients with 47 aneurysms and 8 patients without aneurysms un...
متن کاملEvaluation of Intracranial Dural Arteriovenous Fistulas: Comparison of Unenhanced 3T 3D Time-of-flight MR Angiography with Digital Subtraction Angiography.
PURPOSE We compared gross characterization of intracranial dural arteriovenous fistulas (DAVFs) between unenhanced 3-tesla 3-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) and digital subtraction angiography (DSA). METHODS We subjected 26 consecutive patients with intracranial DAVF to unenhanced 3T 3D TOF MRA and to DSA. Two independent sets of observers inspected ...
متن کاملIntracranial vascular stenosis and occlusive disease: evaluation with CT angiography, MR angiography, and digital subtraction angiography.
BACKGROUND AND PURPOSE Although digital subtraction angiography (DSA) provides excellent visualization of the intracranial vasculature, it has several limitations. Our purpose was to evaluate the ability of helical CT angiography (CTA) to help detect and quantify intracranial stenosis and occlusion compared with DSA and MR angiography (MRA). METHODS Twenty-eight patients underwent CTA, DSA, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 28 3 شماره
صفحات -
تاریخ انتشار 2007