Automated Blood Volume Regulation During Hemodialysis

نویسندگان

  • Isabelle Chapdelaine
  • Clément Déziel
  • François Madore
چکیده

Intradialytic hypotension (IDH) is the most common complication of hemodialysis (HD), occurring in up to 20 to 33% of sessions (Daugirdas, 2001). IDH is responsible for various minor symptoms (nausea, vomiting, muscle cramps, dizziness, and fatigue) during dialysis, but is also associated with more severe adverse events such as myocardial infarction (Burton et al., 2009) and cerebral ischemia (Mizumasa et al., 2004). Moreover, as a result of frequent interruption of sessions and repetitive administration of intravenous fluids, underdialysis and inability to reach dry weight, with subsequent chronic overhydration, can follow. Traditionally, HD prescriptions are based on clinical evaluation and laboratory measurements, and are re-evaluated periodically or when an adverse event, such as hypotension, commands it. The drawback of this prescription is that it relies on previous observations, with the assumption that the same will hold true for the next sessions. Hence, it implies discomfort for the patients, as the actions to remediate to IDH, for example, by stopping ultrafiltration (UF) or adjusting dry weight, are taken on an a posteriori basis (Locatelli et al., 2005). In an attempt to prevent IDH, technological advances have made possible the detection of subclinical predictors of hemodynamic instability, for example relative blood volume variations. With repetitive measurement of such specific parameters during HD (Mercadal & Petitclerc, 2009), actions can be implemented to correct the monitored parameter toward a desired target, with the aim of preventing overt IDH. When this action is automatic and regulated by a closed feedback loop, it is called biofeedback. In this chapter, we will review some of the physiological basis of IDH and blood volume reduction during HD, and we will examine the technical aspects of the various devices used to adjust blood volume during dialysis, with special emphasis on biofeedback systems. Finally, we will study the literature published on the effects of automated blood volume regulation devices on the occurrence of hypotensive episodes, volume overload control, hypertension management and quality of life in chronic HD patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...

متن کامل

Developing a Device for Automated Peritoneal Dialysis

Background: Peritoneal dialysis (PD) is an efficient alternative for hemodialysis. Removal of waste metabolites and excess water from the blood circulation are the two main tasks done during dialysis. These are done by using a filter; in PD, the naturally semi-permeable peritoneal membrane acts as the filter. Automated PD machines control intelligently the operations to enhance the efficiency a...

متن کامل

Continuous Blood Volume Monitoring and Ultrafiltration Control.

Continuous blood volume monitoring (CBVM) is believed to be a promising method for making the determination of patients' "dry weight" more objective, and ultrafiltration (UF) control more appropriate. Although blood volume response to UF and the interrelation between blood volume changes and changes in hemodynamic parameters are highly individual, certain principles of this response and interre...

متن کامل

Assessment of Fluid Shifts of Body Compartments using Both Bioimpedance Analysis and Blood Volume Monitoring

Fluid shifts are commonplace in chronic hemodialysis patients during the intra- and interdialytic periods. In this study, we evaluated fluid shifts of body compartments using both bioimpedance spectroscopy and blood volume monitoring from the start to the end of hemodialysis. 24 stable hemodialysis patients were included on the study. Relative change of blood volume was progressively reduced fr...

متن کامل

Absolute blood volume in hemodialysis patients: why is it relevant, and how to measure it?.

Intradialytic hypotension (IDH) is the most common complication during hemodialysis and is associated with significant morbidity. It occurs as a consequence of a reduction in blood volume during ultrafiltration. Today, devices for monitoring relative blood volume (i.e. the intradialytic blood volume as a fraction of the blood volume at the start of the dialysis treatment) are routinely availabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012