Characterisation of a transparent optical test strip for quantification of water hardness

نویسندگان

  • L. F. Capitán-Vallvey
  • M. D. Fernández-Ramos
  • P. Alvarez de Cienfuegos Gálvez
چکیده

An optical and reversible test strip that uses an ion-exchange mechanism which responds equally to calcium and magnesium and makes it possible to determine water hardness is described. The transparent test strip, made of a polyester sheet, has a circular polymeric film of plasticised poly(vinyl chloride) (PVC) that contains all of the reagents necessary to produce an equal response to calcium and magnesium, namely, a cation-selective neutral ionophore, such as 4,13-[bis(N-adamantylcarbamoyl)acetyl]-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane, a chromoionophore, such as lipophilised Nile Blue, and potassium tetrakis (4-chlorophenyl)borate as a lipophilic salt, which it is evaluated by absorbance measurement at 655 nm in a standard photometer. All experimental variables that influence test strip response, especially in terms of selectivity and response time, have been studied. The sensor responded linearly to hardness up to 14,800 mg l−1, in activities, expressed as CaCO3. The detection limit is 1.9 mg l−1 as CaCO3, the reproducibility intermembrane at a medium level of the range was 7.0%, as R.S.D., of log aCa2+/Mg2+ and 2.6% as intramembrane. The procedure was applied to the determination of hardness in different types of waters (tap, well, mineral and spring) validating results against a reference procedure. This proposed method is quick, inexpensive, selective and sensitive and uses only conventional instrumentation. © 2003 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-situ Fabrication of Transparent Magnesium Aluminate Spinel by Spark Plasma Sintering

Transparent polycrystalline spinel ceramic was fabricated without any sintering aids by spark plasma sintering method of a mixture of Al2O3 and MgO powders for only 10min soak at 1250°C. Densification, microstructure and optical transparency of spinel were examined. The spinel exhibits an in-line transmission of 55% for a visible-wavelength of 470nm and high hardness value of 2040 HV.

متن کامل

Surface Hardness Measurment and Microstructural Characterisation of Steel by X-Ray Diffraction Profile Analysis

An X-ray diffraction line will broaden considerably when steels change into martensitic structure on quenching. The results presented in this paper show that X-ray diffraction technique can be employed for a rapid and nondestructive measurement of hardness of hardened steel. Measurement on various quenched and tempered steels showed that the breadth of its diffraction peak increased with increa...

متن کامل

Resistance Properties of Printed Polyolefin Films using Water-Based Inks

During recent decades due to the increase in pollutants release from various industries, reduction or elimination of volatile organic compounds VOCs has become one of the main purposes of researches in order to protect the environment. In this research, two acrylic emulsion resins and an adhesion promoter polyester emulsion resin were used to optimize water-based printing ink formulation for pr...

متن کامل

Magnesium-selective test strip.

A selective test strip based on an ion-exchange mechanism to determine magnesium is described. This optical and reversible test strip, made on a transparent polyester sheet, has a circular polymeric film of plasticised PVC that contains all of the reagents necessary to produce a response to magnesium, namely, a cation-selective neutral ionophore, 2-amino-N,N'-diheptyl-N,N'-dimethyl-butanediamid...

متن کامل

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003