Rapid image evaluation system for corneal in vivo confocal microscopy.

نویسندگان

  • Christine W Sindt
  • Bruno Lay
  • Helene Bouchard
  • Jami R Kern
چکیده

PURPOSE To develop rapid image processing techniques for the objective analysis of corneal in vivo confocal micrographs. METHODS Perpendicular central corneal volume scans from healthy volunteers were obtained via laser in vivo confocal microscopy. The layer in each volume scan that contained the nerve plexus was detected by applying software operators to analyze image features on the basis of their size, shape, and contrast. Dendritic immune cells were detected in the nerve image on the basis of cellular size, lack of elongation, and brightness relative to the nerves. Images that were 20 μm anterior to the best nerve layer images were used for the analysis of epithelial wing cells; wing cell detection was based on extended regional minima and a watershed transformation. RESULTS The software successfully detected the best nerve layer images in 15 scans from 15 eyes. Manual and automatic analyses were 81.8% in agreement for dendritic immune cells (for 11 cells in a representative image) and 94.4% in agreement for wing cells (for 466 cells in the image). Within 10 seconds per scan, the software calculated the number, mean length, and mean density of immune cells; the number, mean size, and mean density of wing cells; and the number and mean length of nerves. Factors defining the shape and position of cells and nerves also were available. CONCLUSIONS The software rapidly and accurately analyzed the in vivo confocal micrographs of the healthy central corneas, yielding quantitative results to describe the nerves, dendritic immune cells, and wing cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy

Background  To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...

متن کامل

The Reliability and Reproducibility of Corneal Confocal Microscopy in Children.

PURPOSE To assess the image and patient level interrater agreement and repeatability within 1 month for corneal nerve fiber length (CNFL) measured using in vivo corneal confocal microscopy (IVCCM) in children. METHODS Seventy-one subjects (mean [SD] age 14.3 [2.6] years, range 8-18 years; 44 with type 1 diabetes and 27 controls; 36 males and 35 females) were included. 547 images (∼6 images pe...

متن کامل

On-line 3-dimensional confocal imaging in vivo.

PURPOSE In vivo confocal microscopy through focusing (CMTF) can provide a 3-D stack of high-resolution corneal images and allows objective measurements of corneal sublayer thickness and backscattering. However, current systems require time-consuming off-line image processing and analysis on multiple software platforms. Furthermore, there is a trade off between the CMTF speed and measurement pre...

متن کامل

Rapid automated diagnosis of diabetic peripheral neuropathy with in vivo corneal confocal microscopy.

PURPOSE To assess the diagnostic validity of a fully automated image analysis algorithm of in vivo confocal microscopy images in quantifying corneal subbasal nerves to diagnose diabetic neuropathy. METHODS One hundred eighty-six patients with type 1 and type 2 diabetes mellitus (T1/T2DM) and 55 age-matched controls underwent assessment of neuropathy and bilateral in vivo corneal confocal micr...

متن کامل

Fully automatic evaluation of the corneal endothelium from in vivo confocal microscopy

BACKGROUND Manual and semi-automatic analyses of images, acquired in vivo by confocal microscopy, are often used to determine the quality of corneal endothelium in the human eye. These procedures are highly time consuming. Here, we present two fully automatic methods to analyze and quantify corneal endothelium imaged by in vivo white light slit-scanning confocal microscopy. METHODS In the fir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cornea

دوره 32 4  شماره 

صفحات  -

تاریخ انتشار 2013