Switchable multicoil array for MR micro-imaging of breast lesions.
نویسندگان
چکیده
High-resolution breast imaging may improve differentiation between benign and malignant lesions and may be important for refining treatment strategy. This article presents a new, flexible design of a breast-imaging coil capable of providing breast images of a high level of spatial resolution. Referred to as a switchable coil array, the design uses small-diameter surface coils that provide high sensitivity of detection, which, combined with a relatively small field of view, affords a high degree of spatial resolution (up to 200 microm). Remote selection of the coil pair closest to the position of the lesion in the breast permits coverage of the whole breast without changing the position of the coils or the patient. High-resolution MR images of phantom and volunteer patients with benign and malignant breast lesions are presented.
منابع مشابه
Evaluation of multicoil breast arrays for parallel imaging.
PURPOSE To evaluate three multicoil breast arrays for both conventional and SENSE-accelerated imaging. MATERIALS AND METHODS Two commercially available 8-element coils and a prototype 16-element coil were compared. One 8-element array had adjustable coils located next to the breast tissue and the other had a fixed coil arrangement; both were designed to allow parallel imaging in the left-righ...
متن کاملQuantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging
Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...
متن کاملBreast 3 T-MR imaging: indication for stereotactic vacuum-assisted breast biopsy
PURPOSE The purpose of this study was to assess indications for stereotactic vacuum-assisted breast biopsy (SVAB) evaluated by breast 3 T-magnetic resonance (3 T-MR) imaging in patients showing suspicious microcalcifications on mammography and negative ultrasound (US) findings. METHODS AND MATERIALS Fifty-five patients with 55 breast lesions showing suspicious microcalcifications on mammograp...
متن کاملDiagnostic Value of Diffusion-weighted Imaging and Apparent Diffusion Coefficient Values in the Differentiation of Breast Lesions, Histpathologic Subgroups and Correlatıon with Prognostıc Factors using 3.0 Tesla MR.
OBJECTIVE The aim of this study was to evaluate the effect of the apparent diffusion coefficient (ADC) and diffusion-weighted imaging in differentiating benign from malignant breast lesions, histopathologic subtypes of breast tumors, and to find a correlation with prognostic factors using 3T MR. MATERIALS AND METHODS A total of 165 patients aged between 16 and 78 years with 181 histopathologi...
متن کاملSpinal cord MRI in multiple sclerosis with multicoil arrays: a comparison between fast spin echo and fast FLAIR.
OBJECTIVES To compare the sensitivity of fast spin echo (FSE) and of fast fluid attenuated inversion recovery (fast FLAIR) in detecting spinal cord lesions in multiple sclerosis. METHODS With a 1.5 Tesla machine and a multicoil receiver array, FSE images (with two different pixel sizes) and fast FLAIR images of the spinal cord were obtained from 13 patients with multiple sclerosis. RESULTS ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 41 3 شماره
صفحات -
تاریخ انتشار 1999