3D rotational digital subtraction angiography may underestimate intracranial aneurysms: findings from two basilar aneurysms.
نویسندگان
چکیده
3D digital subtraction angiography (DSA) allows clinicians to review intracranial aneurysms and other vascular lesions. We report 2 basilar aneurysms that were imaged by both 3D DSA and DynaCT. These 2 techniques produced very different aneurysm appearances. Anterior portions of the aneurysms were invisible on 3D DSA but were revealed by DynaCT. These aneurysms appeared to have been flattened by image artifacts in 3D DSA. Pulsation and gravity are 2 possible causes of aneurysm underestimation.
منابع مشابه
Clinical usefulness of unsubtracted 3D digital angiography compared with rotational digital angiography in the pretreatment evaluation of intracranial aneurysms.
BACKGROUND AND PURPOSE Three-dimensional digital subtraction angiography (DSA) is useful as a supplement to 2D DSA in the pretreatment evaluation of intracranial aneurysms. However, the clinical efficacy of 3D digital angiography (DA) that is generated from unsubtracted rotational images has not been established. The purpose of this study was to assess whether 3D DA provides additional useful i...
متن کاملIntravenous 3D digital subtraction angiography in the diagnosis of unruptured intracranial aneurysms.
Recent progress in digital subtraction angiography (DSA) devices makes it possible to perform rotational angiography with high resolution and high sensitivity. We tried intravenous (IV) 3D DSA in patients who had undergone MR angiography (MRA) suggestive of unruptured intracranial aneurysms. IV 3D DSA can be used as an alternative method for imaging unruptured intracranial aneurysms suggested o...
متن کامل3D Rotational Angiography in Follow-Up of Clipped Intracranial Aneurysms
Introduction. 3D Rotational Angiography (RA) is indispensable for evaluation of intracranial aneurysms, providing infinite viewing angles and defining the aneurysm morphology. Its role in follow-up of clipped aneurysms remains unclear. We aimed to compare the aneurysm residue/recurrence detection rate of 3D RA with 2D digital subtraction angiography (DSA). Methods. 47 patients harboring 54 clip...
متن کاملComparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms.
BACKGROUND AND PURPOSE Rotational angiography (RA) and digital subtraction angiography (DSA) together may depict more intracranial aneurysms than DSA alone. We compared the diagnostic value of 3D RA and biplanar DSA in detecting, classifying, and planning treatment for ruptured intracranial aneurysms. METHODS A total of 53 patients with acute subarachnoid hemorrhage (Hunt and Hess grades I-V)...
متن کاملImproved Visualization of Intracranial Vessels with Intraoperative Coregistration of Rotational Digital Subtraction Angiography and Intraoperative 3D Ultrasound
INTRODUCTION Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. METHODS We analyzed 3D intraoperative ultrasound in 39 patients wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 28 9 شماره
صفحات -
تاریخ انتشار 2007