Comparison of lysis filtration and an automated blood culture system (BACTEC) for detection, quantification, and identification of odontogenic bacteremia in children.

نویسندگان

  • Victoria S Lucas
  • Vasiliki Lytra
  • Thoraya Hassan
  • Helen Tatham
  • M Wilson
  • Graham J Roberts
چکیده

Lysis filtration (LyF) was compared with BACTEC PAEDS PLUS in estimating the prevalence of, and sensitivity for, detection of odontogenic bacteremia. Both real bacteremia and simulated bacteremia (seeded blood or saline samples) were assessed to determine the validity of LyF in estimating bacteremia. The simulated bacteremia was also used to assess the reliability of LyF to estimate intensity of bacteremia in CFU per milliliter of blood. Reference organisms were used to assess the abilities of LyF and BACTEC to isolate known oral streptococci. There was no difference in the number of CFU per milliliter of seeded saline, seeded blood, and drop cultures of the organisms plated directly onto agar. Blood cell volume had a negligible effect on the yield of organisms for simulated bacteremia. When LyF and BACTEC were compared, the time to detection of bacteremia was always significantly shorter for BACTEC. For aerobic cultures, these times were 43.7 and 9.6 h, respectively (P < 0.01). For anaerobic cultures, these times were 45.1 and 9.9 h, respectively (P < 0.01). These differences occurred as well for bacteremia following the extraction of a single tooth, with LyF and BACTEC aerobic cultures taking 78 and 30.5 h, respectively (P < 0.0001). For anaerobic cultures, the times were 90.8 and 45 h, respectively (P < 0.0004). A preextraction bacteremia was detected on 2.1% of occasions with BACTEC compared to 31% of occasions with LyF (P < 0.05) The use of LyF was an effective and reliable means of estimating the intensity of pre- and postextraction bacteremia. The values were 3.6 and 5.9 CFU/ml, respectively (P < 0.4729), and the difference was not statistically significant. In summary, BACTEC is quicker than LyF, but less sensitive. LyF provides additional important information in estimating the intensity of bacteremia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تشخیص بروسلوز با استفاده از سیستم کشت خون ‌ BACTECو تائید نتایج آن با PCR

Abstract: Brucellosis is one of the most common zoonotic diseases in Iran. Growth of Brucella is slow and blood cultures of these bacteria are time-consuming via classical methods. We try to evaluate BACTEC 9120 system capacity in order to detect of bacteremia due to Brucella spp and to confirm isolated bacteria by PCR. Blood culture sample of 102 suspected patients evaluated by BACTEC 9120 sys...

متن کامل

Clinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children.

The Isolator 1.5 microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington , Del.) was compared with the BACTEC radiometric detection system (Johnston Laboratories, Inc., Cockeysville, Md.) for the detection of bacteremia in children. The Isolator 1.5 is a blood culture system designed for small volumes of blood (0.5 to 1.5 ml). The method involves lysis of the cells of the patient and t...

متن کامل

Rapid automated disgnosis of bacteremia by impedance detection.

Lysis and filtration of blood culture specimens were combined with impedance detection of bacterial growth to facilitate the diagnosis of bacteremia. A blood lysis-filtration technique (Zierdt et al., 1976) was coupled to a simple, inexpensive automated detection system. The practical and technical aspects of the impedance detection system are discussed. This new blood culturing system was comp...

متن کامل

بررسی سطح اندوتوکسین خون بیماران همودیالیزی و مقایسه آن با کشت خون

Introduction: Presently, bacteremia is the principal cause of morbidity in patients undergoing hemodialysis. Gram-negative bacteria account for approximately 50 percent of documented infections. Endotoxins released during lysis of gram negative bacteremia result in inflammatory and defense response by the body and if not treated promptly result in septic shock and ultimately death of the patie...

متن کامل

Advantages of BACTEC hypertonic culture medium for detection of Haemophilus influenzae bacteremia in children.

The hypertonic and aerobic culture media in the BACTEC system were compared for the detection of Haemophilus influenzae bacteremia in children. Of 1,611 blood cultures, 30 were positive for this pathogen. The aerobic and hypertonic media gave positive results in 28 and 29 cultures, respectively. Within the first 12 h, H. influenzae was detected in the hypertonic medium in 48.5% of the positive ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 40 9  شماره 

صفحات  -

تاریخ انتشار 2002