Multisite immunochemiluminometric assay for simultaneously measuring whole-molecule and amino-terminal fragments of human parathyrin.

نویسندگان

  • G G Klee
  • C M Preissner
  • P G Schryver
  • R L Taylor
  • P C Kao
چکیده

The immunochemiluminometric assay described uses immobilized anti-human parathyrin (parathyroid hormone, hPTH)(1-44) and anti-hPTH(44-68) antisera and acridinium ester-labeled anti-hPTH(1-34) to simultaneously measure both intact hPTH and its amino-terminal fragments. Results by the assay correlate well with those by a cAMP-based bioassay and the Nichols Allegro immunoradiometric assay. The minimal detection limit is 0.08 pmol/L. The normal range is 1.0-5.0 pmol/L, and values are higher in older women. About 90% of study patients with surgically proven parathyroid adenomas had above-normal preoperative PTH concentrations, whereas patients with hypercalcemia of malignancy had normal or suppressed values. This assay was designed to detect both intact PTH and amino-terminal PTH fragments; however, chromatographic fractionation of pools of primary and secondary hyperparathyroid plasma showed virtually no amino-terminal fragment activity. Nonetheless, the design is important because the absence of carboxyl-terminal binding sites prevents interference by carboxyl-terminal fragments and because bioactive amino-terminal fragments will react in the assay if they are present in the patients' sera or if they are produced by in vitro proteolysis of intact PTH.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical and laboratory evaluation of a radioimmunoassay kit for measuring the mid-molecule fraction of parathyrin.

We report the results of a laboratory and clinical evaluation of a commercial kit procedure (Immuno Nuclear Corp.) for measuring the mid-region of the parathyrin molecule. The estimated dose at 50% binding averaged 130 pmol/L, and the minimum detectable concentration was 14 pmol/L. The within-assay CV was less than or equal to 6.6%, the between-assay CV less than or equal to 12.5%. Relative ana...

متن کامل

Two-site immunochemiluminometric assay of intact human parathyrin in serum with use of a tracer peptide purified by reversed-phase high-performance liquid chromatography.

For this two-site immunochemiluminometric assay of intact human parathyrin (hPTH), the luminescent tracer was synthetic hPTH(53-84), conjugated via succinimide linkage to (aminobutyl)ethyl-isoluminol hemisuccinimide (abei-h). Purification of the labeled hPTH(53-84) by reversed-phase high-performance liquid chromatography allowed isolation of the conjugate having the highest incorporation of abe...

متن کامل

Development and validation of a new radioimmunoassay for parathyrin (PTH).

A radioimmunoassay for human parathyrin has been developed and characterized with whole-molecule (residues 1-84) human parathyrin and with the 1-34, 44-68, and 53-84 amino acid residue fragments of it. The antiserum used reacted with the whole molecule and with the 44-68 and 53-84 fragments, but not with the 1-34 fragment. Parathyrin concentrations in the serum of 118 normal subjects and of 112...

متن کامل

Diagnostic utility of C-terminal parathyrin measurement as compared with measurements of N-terminal parathyrin and calcium in serum.

We compared results obtained from two parathyrin (parathyroid hormone) assays with differing specificities, using sera from 172 normal donors and from 98 patients with disorders of calcium regulation. Intact parathyrin was measured in both assays; the C-parathyrin assay also measured the 53-84 amino acid C-terminal hormone fragment; the N-parathyrin assay also measured the 1-34 N-terminal fragm...

متن کامل

C-terminal parathyrin (parathyroid hormone) radioimmunoassay in serum with commercially available reagents.

We describe a sequential double-antibody assay for measuring C-terminal parathyrin in serum with commercially available reagents. Intact bovine hormone, used as a working standard, is iodinated by conventional Chloramine T procedures. The antibody affinity is characteristic of high affinity binding (1.4 to 1.6 x 10(10) L/mol of intact parathyrin). The antibody also cross reacts with a C-termina...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 5  شماره 

صفحات  -

تاریخ انتشار 1992