Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method
نویسندگان
چکیده
A simple, sensitive, and accurate RP-HPLC coupled with UV detector method was developed and validated for simultaneous determination of matrine and tinidazole in compound lotion. The chromatographic separation of the two compounds was carried out with a SinoChoom ODS-BP C18 column (5 μ m, 4.6 mm × 200 mm) analytical column, using a mobile phase consisting of 0.025 mol/L potassium dihydrogen phosphate (containing triethylamine 0.05%, v/v) and acetonitrile (80 : 20, v/v) at a flow rate of 1.0 mL/min. The detection was monitored at 210 and 310 nm for matrine and tinidazole, respectively. Total run time was 12 min, and the column was maintained at 25°C. The excipients in the compound lotion did not interfere with the drug peaks. The calibration curves of matrine and tinidazole were fairly linear over the concentration ranges of 10.0-100.0 μ g/mL (r = 0.9954) and 20.0-200.0 μ g/mL (r = 0.9968), respectively. The RSD of both the intraday and interday variations was below 1.5% for matrine and tinidazole. The proposed HPLC method was validated according to International Conference on Harmonisation and proved to be suitable for the simultaneous determination of matrine and tinidazole in compound lotion.
منابع مشابه
Simultaneous Determination of Co-formulated Matrine and Secnidazole in Suppositories by Reverse Phase High Performance Liquid Chromatography
Purpose: To develop and validate a new, simple, sensitive and accurate high performance liquid chromatographic (HPLC) method for the simulataneous determination of matrine and secnidazole in suppositories. Methods: The method involved using a SinoChoom ODS-BP C18 column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of acetonitrile–triethylamine (0.05 %) in 0.025 mol/L KH2PO4 (20:80, v/v)....
متن کامل[Determination of four alkaloids in compound Kushen Injection by high performance liquid chromatography with ionic liquid as mobile phase additive].
In order to improve the resolution and peak shape, 1-butyl-3-methylimidazolium tetrafluoroborate ( [ BMIM] BF4 ) was used as mobile phase additive to develop an HPLC method for the determination of four main alkaloids in Compound Kushen Injection. An Agilent TC-C18 column was used with the mobile phase of methanol-0.1% phosphoric acid solution (containing 2. 2 x 10(4) mol/L [BMIM] BF4 ) (5: 95,...
متن کاملRP-HPLC/pre-column derivatization for analysis of omeprazole, tinidazole, doxycycline and clarithromycin.
A validated, reliable and accurate reversed-phase high performance liquid chromatographic method using pre-column derivatization was adopted for the simultaneous determination of two ternary mixtures containing omeprazole, tinidazole and doxycycline hyclate or clarithromycin. Separation was achieved on a C18 column, through a gradient elution system using acetonitrile-methanol-water adjusted to...
متن کاملAssay Method Development and Validation for Simultaneous Quantitative Estimation of Diloxanide Furoate and Tinidazole in Tablets by Rp-hplc
Objective: To develop an accurate, precise and linear Reverse-Phase High-Performance Liquid Chromatographic (RP-HPLC) method for simultaneous quantitative estimation of Diloxanide furoate and Tinidazole in tablets and validate as per ICH guidelines. Methods: The optimized method uses a reverse phase column, Waters Symmetry C18 (250 X 4.6 mm; 5μ), a mobile phase of triethylammonium phosphate buf...
متن کاملSimultaneous determination of paracetamol, 4-Aminophenol, 4-Chloroacetanilid, Benzyl alcohol,Benzaldehyde and EDTA by HPLC methodin paracetamol injection ampoule
Paracetamol that is known as acetaminophen have the most consume as an analgesic and antipyreticdrug in the world. That is formulated in single compound or mixture at many forms such astablets, syrups, suspensions and drops. The last form is intravenous injections. Paracetamol derivedfrom 4-minophenol which is synthesized by acylated the P-acetaminophenol and acetic anhydride.4-aminophenol is t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013