Determination of Actual Object Size Distribution from Direct Imaging
نویسندگان
چکیده
Direct imaging is a technique commonly used in the study of particle, bubble, and droplet size distribution in a dynamic system. Objects such as particles, bubbles, and droplets can be present at various distances from the imaging device when images are captured. Hence, the location of the object will need to be known in order to determine the actual size of an individual object. However, the location of the object cannot be determined from a single image. A single calibration scale defined at the focusing plane is normally used for the determination of all the object sizes from images. When the focus is close to the imaging device, the change in magnification with location is large. The size distribution obtained from the use of a single calibration scale would thus give a considerable deviation from the actual size distribution. In this study, a statistical method is proposed to reconstruct the actual object size distribution from the experimental object size distribution obtained from images using a single calibration scale defined at the focusing plane. Experiments are performed to validate the accuracy of the proposed method on the particle size distribution determination in a settling system. The stability of the proposed method is also analyzed theoretically for imaging devices with different depth-of-field (DOF), focusing location, and change in magnification with distance.
منابع مشابه
-
In this paper a method for digitally recording four quarter-reference-wave-holograms (by CCD) in a Mach-Zehnder interferometer setup, and reconstructing the object wave-front by numerical method is presented. The terms of direct transmission, auto-correlation and conjugate wave in the four wave reconstruction are cancelled out and only one original object wave is left after overlapping. Reconst...
متن کاملA mixed Bayesian/Frequentist approach in sample size determination problem for clinical trials
In this paper we introduce a stochastic optimization method based ona mixed Bayesian/frequentist approach to a sample size determinationproblem in a clinical trial. The data are assumed to come from a nor-mal distribution for which both the mean and the variance are unknown.In contrast to the usual Bayesian decision theoretic methodology, whichassumes a single decision maker, our method recogni...
متن کاملTomographic Determination of Temperature Distribution in Billets (RESEARCH NOTES)
The principles of Ultrasonic Computed Tomography (UCT) are reviewed in this paper. The UCT is a powerful nondestructive technique in medicine and recently in industry to reveal an image of a slice of an object or body. The advantage of UCT over other conventional techniques in imaging is that a computed tomogram yields quantitative information about the section of interest. Experimental works o...
متن کاملSegmentation Assisted Object Distinction for Direct Volume Rendering
Ray Casting is a direct volume rendering technique for visualizing 3D arrays of sampled data. It has vital applications in medical and biological imaging. Nevertheless, it is inherently open to cluttered classification results. It suffers from overlapping transfer function values and lacks a sufficiently powerful voxel parsing mechanism for object distinction. In this work, we are proposing an ...
متن کاملارزیابی دقت دو دستگاه آپکس یاب الکترونیکی (Electronic Apex Locator) از نسل چهارم در تعیین طول کانال (In-vivo)
Background and Aim: Determining correct working length in root canal therapy is of great importance in successful treatment. The purpose of this study was to compare the accuracy of two electronic apex locators of fourth generation, Raypex4 and Apit7, in determining working length in vivo. Materials and Methods: In this test evaluation study performed at Dental School of Tehran University, a to...
متن کامل