Frequently missed abdominal compartment syndrome.
نویسندگان
چکیده
Intra-abdominal pressure (Intra-abdominal pressure – IAP) is defined as static pressure inside abdominal cavity, that fluctuates with respiration, physical exercise and change in body position. It is determined by total volume of internal organs and concurrent organ dysfunction (blood, fluid, tumors or factors reducing relaxation of abdominal walls). IAP should be expressed in (mm Hg)and measured at the end of expiration with patient in supine position, with no abdominal contractions. Clinical assessment of IAP is of little sensitivity and inadequate. There are two methods of IAP measurement: direct – intraoperative, using trocar or drain located in peritoneal cavity, and indirect – recording intra-abdominal pressure in gastric cavity, anus, vena cava inferior, and urine bladder (Intra-Vesical Pressure; IVP). IVP is the easiest and the fastest method to measure IAP and serves nowadays as the golden standard. It was first introduced by Kron in 1948 (1). It is done through indwelling bladder catheter, instilling 50-100 ml of sterile saline into the bladder connected to a T-connector. The catheter is then clamped and intravesical pressure is measured, at the end of expiration, using manometer/pressure transducer connected to the other arm of the Tconnector. The symphysis pubis is used as a zero reference point. During this procedure the urine bladder wall, with such filling, is assumed to act as membrane that transfers intra-abdominal pressure fluctuations (2, 3, 4). The disadvantage of such method is that in case of spastic bladder and intraperitoneal adhesions – due to lack of pressure transduction between different regions of abdominal cavity – IVP does not reflect IAP.
منابع مشابه
Comparison of Intra-abdominal Pressure Measurement and Physical Exam for Diagnosis of Surgery Indication in Patients with Abdominal Compartment Syndrome due to Blunt Trauma
Background & Aims: Increase in abdominal pressure can lead to the so-called intra–abdominal compartment syndrome (ACS) that is often observed during the first 24 hours after sever abdominal trauma and surgery. Measurement of the intra abdominal pressure through the bladder as a non-invasive measurement can provide a quick and accurate assessment of abdominal pressure changes. This study was per...
متن کاملAbdominal Compartment Syndrome after Cesarean Section: A Case Report
Background: Abdominal compartment syndrome (ACS) after cesarean section (CS) is a rare event which is associated with an increased risk of morbidity and mortality. This complication may arise as a result of musculoskeletal trauma and fluid accumulation. The present report aimed to introduce a case of ACS after the cesarean section. Case report: We present...
متن کاملAbdominal compartment syndrome: a concise clinical review.
OBJECTIVE There has been an increased awareness of the presence and clinical importance of abdominal compartment syndrome. It is now appreciated that elevations of abdominal pressure occur in a wide variety of critically ill patients. Full-blown abdominal compartment syndrome is a clinical syndrome characterized by progressive intra-abdominal organ dysfunction resulting from elevated intra-abdo...
متن کاملCryptic but Deadly: A Serious Killer in Patients with Advanced Liver Disease that Should Not Be Missed
Cryptococcal peritonitis is an under-recognized disease that is an important cause of mortality in end-stage liver disease. We report a 43-year old male with decompensated cirrhosis secondary to refractory autoimmune hepatitis on immunosuppression with hepatocellular carcinoma who developed cryptococcal peritonitis. The patient subsequently developed ischemic bowel and multisystem organ failure...
متن کاملAbdominal compartment syndrome.
Acute renal failure frequently occurs in the intensive care unit as a primary or secondary event in association with trauma, surgery, or comorbid medical disease. An increasingly common thread linking surgical and medical disease management is the abdominal compartment syndrome. In particular, the rise of early goal-directed therapy for the initial resuscitation and management of severe sepsis ...
متن کاملPressure Measurement Techniques for Abdominal Hypertension: Conclusions from an Experimental Model
Introduction. Intra-abdominal pressure (IAP) measurement is an indispensable tool for the diagnosis of abdominal hypertension. Different techniques have been described in the literature and applied in the clinical setting. Methods. A porcine model was created to simulate an abdominal compartment syndrome ranging from baseline IAP to 30 mmHg. Three different measurement techniques were applied, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Polski przeglad chirurgiczny
دوره 84 8 شماره
صفحات -
تاریخ انتشار 2012