Comparison of approaches to quantify arterial damping capacity from pressurization tests on mouse conduit arteries.
نویسندگان
چکیده
Large conduit arteries are not purely elastic, but viscoelastic, which affects not only the mechanical behavior but also the ventricular afterload. Different hysteresis loops such as pressure-diameter, pressure-luminal cross-sectional area (LCSA), and stress-strain have been used to estimate damping capacity, which is associated with the ratio of the dissipated energy to the stored energy. Typically, linearized methods are used to calculate the damping capacity of arteries despite the fact that arteries are nonlinearly viscoelastic. The differences in the calculated damping capacity between these hysteresis loops and the most common linear and correct nonlinear methods have not been fully examined. The purpose of this study was thus to examine these differences and to determine a preferred approach for arterial damping capacity estimation. Pressurization tests were performed on mouse extralobar pulmonary and carotid arteries in their physiological pressure ranges with pressure (P) and outer diameter (OD) measured. The P-inner diameter (ID), P-stretch, P-Almansi strain, P-Green strain, P-LCSA, and stress-strain loops (including the Cauchy and Piola-Kirchhoff stresses and Almansi and Green strains) were calculated using the P-OD data and arterial geometry. Then, the damping capacity was calculated from these loops with both linear and nonlinear methods. Our results demonstrate that the linear approach provides a reasonable approximation of damping capacity for all of the loops except the Cauchy stress-Almansi strain, for which the estimate of damping capacity was significantly smaller (22 ± 8% with the nonlinear method and 31 ± 10% with the linear method). Between healthy and diseased extralobar pulmonary arteries, both methods detected significant differences. However, the estimate of damping capacity provided by the linear method was significantly smaller (27 ± 11%) than that of the nonlinear method. We conclude that all loops except the Cauchy stress-Almansi strain loop can be used to estimate artery wall damping capacity in the physiological pressure range and the nonlinear method is recommended over the linear method.
منابع مشابه
Comparison of the right internal thoracic artery and radial artery as a second arterial conduit in ‘Y’ composite fashion in patients undergoing coronary artery bypass grafting using total arterial revascularization
Introduction: The use of two arterial conduits for CABG is rapidly increasing. The second arterial conduit to LITA is usually RITA or radial artery. We sought to compare outcomes when either RITA or radial artery is exclusively used as a Y composite graft to LITA for total arterial revascularization. Material and methods: We retrospectively analyzed 231 ...
متن کاملTraining induces nonuniform increases in eNOS content along the coronary arterial tree.
Exercise training produces enhanced nitric oxide (NO)-dependent, endothelium-mediated vasodilator responses of porcine coronary arterioles but not conduit coronary arteries. The purpose of this study was to test the hypothesis that exercise training increases the amount of endothelial NO synthase (eNOS) in the coronary arterial microcirculation but not in the conduit coronary arteries. Miniatur...
متن کاملComparision of Methods for Determining Bearing Capacity of Piles Using Standard Penetration Test (SPT) Data
In recent years, determining bearing capacity of piles from in-situ testing data as a complement to static and dynamic analysis has been used by geotechnical engineers. In this paper, different approaches for estimating bearing capacity of piles from SPT data are studied and compared. A new method based on N value from SPT is presented. Data averaging, failure zone and plunging failure of pil...
متن کاملComparision of Methods for Determining Bearing Capacity of Piles Using Standard Penetration Test (SPT) Data
In recent years, determining bearing capacity of piles from in-situ testing data as a complement to static and dynamic analysis has been used by geotechnical engineers. In this paper, different approaches for estimating bearing capacity of piles from SPT data are studied and compared. A new method based on N value from SPT is presented. Data averaging, 
failure zone and plunging failure of p...
متن کاملEndothelial barrier dysfunction in diabetic conduit arteries: a novel method to quantify filtration.
The endothelial barrier plays an important role in atherosclerosis, hyperglycemia, and hypercholesterolemia. In the present study, an accurate, reproducible, and user-friendly method was used to further understand endothelial barrier function of conduit arteries. An isovolumic method was used to measure the hydraulic conductivity (L(p)) of the intact vessel wall and medial-adventitial layer. No...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanical engineering
دوره 135 5 شماره
صفحات -
تاریخ انتشار 2013