Comparison of automated and manual nucleic acid extraction methods for detection of enterovirus RNA.

نویسندگان

  • Julia H Knepp
  • Melissa A Geahr
  • Michael S Forman
  • Alexandra Valsamakis
چکیده

Automated nucleic acid extraction is an attractive alternative to labor-intensive manual methods. We compared two automated methods, the BioRobot M48 instrument (Qiagen, Inc.) and MagNA Pure (Roche Applied Sciences) methods, to two manual methods, the QIAamp Viral RNA Mini kit (Qiagen) and TRIzol (Invitrogen), for the extraction of enterovirus RNA. Analytical sensitivity was assessed by dilution analysis of poliovirus type 2 Sabin in cerebrospinal fluid. The sensitivity of PCR was equivalent after RNA extraction with QIAamp, BioRobot M48, and MagNA Pure. All 18 replicates of 100 PFU/ml were detected after extraction by the four methods. Fewer replicates of each successive dilution were detected after extraction by each method. At 10(-1) PFU/ml, 17 of 18 replicates were positive by QIAamp, 15 of 18 replicates were positive by BioRobot M48, and 12 of 18 replicates were positive by MagNA Pure; at 10(-2) PFU/ml, 4 of 17 replicates were positive by QIAamp, 2 of 18 replicates were positive by BioRobot M48, and 0 of 18 replicates were positive by MagNA Pure. At 10(-3) PFU/ml, no replicates were detected. Evaluation of TRIzol was discontinued after nine replicates due to a trend of lower sensitivity (at 10(-3) PFU/ml eight of nine replicates were positive at 100 PFU/ml, four of nine replicates were positive at 10(-1) PFU/ml, and zero of nine replicates were positive at 10(-2) PFU/ml). Concordant results were obtained in 24 of 28 clinical specimens after extraction by all methods. No evidence of contamination was observed after extraction by automated instruments. The data indicate that the sensitivity of enterovirus PCR is largely similar after extraction by QIAamp, BioRobot M48, and MagNA Pure; a trend of decreased sensitivity was observed after TRIzol extraction. However, the results of enterovirus PCR were largely concordant in patient samples, indicating that the four extraction methods are suitable for detection of enteroviruses in clinical specimens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Detection of COVID-19 by RT-LAMP PCR Technique and its Comparison with Real-Time RT-PCR Method

Rapid antigen and antibody, serological tests, and RT ‑ PCR-based molecular methods are widely used for the detection of microorganisms worldwide. Objectives: This study aimed by Isothermal nucleic acid amplification techniques to detect the covid-19. Methods: In this study, 200 samples of nasopharynx and oropharynx were collected from Jamaran Heart Hospital in Tehran. Covid -19 was exami...

متن کامل

Comparison between RT-PCR, NASBA and RT-LAMP Methods for Detection of Coxsackievirus B3

Viral myocarditis is a moderate disease, but it sometimes causes progressive cardiac disorder. Many different viruses have been considered as the agent of viral myocarditis, but Coxsackievirus of the B group, in particular of the Coxsackievirus B3 (CVB3), is more than fifty percent of cases of viral myocarditis. CVB3 is a positive single-stranded RNA virus and a member of the genus Enterovirus ...

متن کامل

Multicenter comparison of nucleic acid extraction methods for detection of severe acute respiratory syndrome coronavirus RNA in stool specimens.

The emergence of a novel coronavirus (CoV) as the cause of severe acute respiratory syndrome (SARS) catalyzed the development of rapid diagnostic tests. Stool samples have been shown to be appropriate for diagnostic testing for SARS CoV, although it has been recognized to be a heterogeneous and difficult sample that contains amplification inhibitors. Limited information on the efficiency of ext...

متن کامل

Comparison of a Selection of Rapid Automated DNA and RNA Extraction Technologies for Detection of Somatic or Constitutional Gene Abnormalities in Cancer Diagnosis

Molecular analyses of large numbers of patient samples are increasingly used for diagnostic applications as well as for understanding cancer biology. Their accuracy depends on the quality and quantity of nucleic acids extracted from human cells or tissues. To optimize these preanalytical steps, we evaluated several automated technologies for nucleic acid purification from clinical samples. Thre...

متن کامل

Nucleic acid extraction from formalin-fixed paraffin-embedded cancer cell line samples: a trade off between quantity and quality?

BACKGROUND Advanced genomic techniques such as Next-Generation-Sequencing (NGS) and gene expression profiling, including NanoString, are vital for the development of personalised medicines, as they enable molecular disease classification. This has become increasingly important in the treatment of cancer, aiding patient selection. However, it requires efficient nucleic acid extraction often from...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 41 8  شماره 

صفحات  -

تاریخ انتشار 2003