Dosimetric effects of prone and supine positions on post-implant assessments for prostate brachytherapy

نویسندگان

  • Toshio Ohashi
  • Tetsuo Momma
  • Shoji Yamashita
  • Kunimitsu Kanai
  • Yusuke Watanabe
  • Takashi Hanada
  • Naoyuki Shigematsu
چکیده

PURPOSE Post-implant dosimetric assessment is essential for optimal care of patients receiving prostate brachytherapy. In most institutions, post-implant computed tomography (CT) is performed in the supine position. This study aimed to assess variability in dosimetric parameters with postural changes during acquisition of post-implant CT scans. MATERIAL AND METHODS In total, 85 consecutive patients were enrolled in this study. Fifty-three patients underwent seed implantation alone, and the remaining 32 received a combination of seed implantation and external beam radiotherapy. For post-implant analyses, CT scans were obtained in two patient positions, supine and prone. To evaluate differences in dosimetric parameters associated with postural change, the dosimetric data obtained in the supine position were defined as the standard. RESULTS The median prostate volume was 22.4 ml in the supine and 22.5 ml in the prone position (p = 0.51). The median prostate D90 was 120.1% in the supine and 120.3% in the prone position, not significantly different. The mean prostate V100 was 97.1% in the supine and 97.0% in the prone position, again not significantly different. Median rectal V100 in supine and prone positions were 0.42 ml and 0.33 ml, respectively (p < 0.01). Rectal D2cc was also significantly decreased in the prone as compared with the supine position (median, 59.1% vs. 63.6%; p < 0.01). A larger post-implant prostate volume was associated with decreased rectal doses in the prone position. CONCLUSIONS Though there were no significant differences among prostate D90 assessments according to postural changes, our results suggest that post-implant rectal doses decreased in the prone position.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Comparison of the Effects of Prone and Supine Positions on Abdominal Distention in the Premature Infants Receiving Nasal Continuous Positive Airway Pressure (NCPAP)

Background: Premature infants with respiratory distress syndrome (RDS) are in dire need of respiratory support with a ventilator. However, the high tidal volume of mechanical ventilation may cause lung injury, and researchers have been concerned with the use of nasal continuous positive airway pressure (NCPAP). NCPAP has concomitant side effects, such as abdominal distention, which might disrup...

متن کامل

The role of supine and prone positions on central nervous system involvement in patients with acute lymphoblastic leukemia

Background: Acute lymphoblastic leukemia (ALL) affects both children and adults, with a peak incidence between the ages of 2 and 5 years. ALL cells sometimes penetrate the central nervous system (CNS) and patients with CNS diseases at initial presentation have been reported to experience a significantly greater risk of treatment failure compared with CNS negative patients. This study hypothesiz...

متن کامل

SU-E-T-465: Exploring the Dosimetric and Tumor Control Consequences of Prostate Seed Loss and Migration.

PURPOSE Once implanted, prostate brachytherapy seeds are vulnerable to loss and movement. A general estimation of these effects may be useful for making patient care decisions when seeds are lost after the post-implant scan. The goal of this work was to explore the dosimetric and radiobiological effects of the types of seed loss and migration common in prostate brachytherapy. METHODS This stu...

متن کامل

Evaluation of the dosimetric impact of loss and displacement of seeds in prostate low-dose-rate brachytherapy

PURPOSE To analyze the seed loss and displacement and their dosimetric impact in prostate low-dose-rate (LDR) brachytherapy while utilizing the combination of loose and stranded seeds. MATERIAL AND METHODS Two hundred and seventeen prostate cancer patients have been treated with LDR brachytherapy. Loose seeds were implanted in the prostate center and stranded seeds in the periphery of the gla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2013