Natural and CVD type diamond detectors as dosimeters in hadrontherapy applications

نویسندگان

  • G.A.P. Cirrone
  • G. Cuttone
چکیده

Diamond is potentially a suitable material for use as radiation dosimeter; the wide band gap results in low dark currents and low sensitivity to visible light, the high carrier mobility can give rapid response, the very high density of strong bonds in the crystal structure make diamond very resistant to radiation damage; moreover it is tissue equivalent. The more recent advances in the synthesis of polycrystalline diamond by chemical vapour deposition (CVD) techniques have allowed the synthesis of material with electronic properties suitable for dosimetric application. In this paper we will report the results obtained in the study of the response of a natural diamond dosimeter and a CVD one irradiated with 62 AMeV proton beams to demonstrate their possible application in protontherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CVD diamond detectors as dosimeters for radiotherapy

The use of diamonds detectors in radiotherapy and its potential advantages over silicon diodes and ionisation chambers is reviewed. Preliminary results on the performance of CVD diamond detectors in an X-ray beam will be presented. While the devices are sufficiently sensitive, applications as dosimeters are at present limited by time dependent effects. Prospects for further work are described. ...

متن کامل

Synthetic diamonds for heavy-ion therapy dosimetry

In this paper we report on first results obtained using polycrystalline CVD diamond detectors irradiated with heavily ionizing particles at GSI. At the UNILAC accelerator, ions with energies near the Bragg-Peak have been stopped inside the material whereas at the heavy-ion therapy facility of GSI these detectors are operated in transmission mode and have been studied in a carbon beam from SIS w...

متن کامل

Dosimetric characteristics of active solid state detectors in a 60 MeV proton radiotherapy beam

The solid state active detectors, widely used for conventional radiotherapy, such as diamond detectors (DD) and diodes may be attractive tools also in dosimetry of therapeutic proton beams. Diodes are broadly applied in oncology clinics and routinely used for in-vivo dosimetry [1, 8]. These real-time detectors are rugged, relatively inexpensive and provide on-line readings, what allows for quic...

متن کامل

Designing Optimal Bias Voltage for Radiotherapy Diamond Dosimeter

Introduction: Recent developments of radiotherapy techniques, require high accuracy detectors to determine the delivered dose in a small area. Chemical vapor deposition (CVD) or naturally growth diamond detectors which are commercially available are good candidates for this purpose. In these detectors two electrodes with high different electrical potential are deposited on both...

متن کامل

First Applications of CVD-Diamond Detectors in Heavy-ion Experiments

Test measurements with 241Am-α-particles, 12C, 20Ne, 58Ni, 208Pb and 238U projectiles are performed. It is shown that the most important charactristics of heavy-ion diamond detectors are described by the shaping parameters of the detectors single pulse. Distributions of rise and decay times of the signals as well as of the associated charge amplitudes are discussed. An intrinsic time resolution...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003