Regional correlation of emphysematous changes in lung function and structure: a comparison between pulmonary function testing and hyperpolarized MRI metrics.
نویسندگان
چکیده
Regional and global relationships of lung function and structure were studied using hyperpolarized ³He MRI in a rat elastase-induced model of emphysema (n = 4) and healthy controls (n = 5). Fractional ventilation (r) and apparent diffusion coefficient (ADC) of ³He were measured at a submillimeter planar resolution in ventral, middle, and dorsal slices 6 mo after model induction. Pulmonary function testing (PFT) was performed before MRI to yield forced expiratory volume in 50 ms (FEV₅₀), airway resistance (R(I)), and dynamic compliance (C(dyn)). Cutoff threshold values of ventilation and diffusion, r* and ADC*, were computed corresponding to 80% population of pixels falling above or below each threshold value, respectively. For correlation analysis, r* was compared with FEV₅₀/functional residual capacity (FRC), R(I) and C(dyn), whereas ADC* was compared with FEV₅₀/FRC, total lung capacity (TLC), and C(dyn). Regional correlation of r and ADC was evaluated by dividing each of the three lung slices into four quadrants. C(dyn) was significantly larger in elastase rats (0.92 ± 0.16 vs. 0.61 ± 0.12 ml/cmH₂O). The difference of R(I) and FEV₅₀ was insignificant between the two groups. The r* of healthy rats was significantly larger than the elastase group (0.42 ± 0.03 vs. 0.28 ± 0.06), whereas ADC* was significantly smaller in healthy animals (0.27 ± 0.04 vs. 0.36 ± 0.01 cm²/s). No systematic difference in these quantities was observed between the three lung slices. A significant 33% increase in ADC* and a significant 31% decline in r* for elastase rats was observed compared with a significant 51% increase in C(dyn) and a nonsignificant 26% decline in FEV₅₀/FRC. Correlation of imaging and PFT metrics revealed that r and ADC divide the rats into two separate clusters in the sample space.
منابع مشابه
Early changes of lung function and structure in an elastase model of emphysema--a hyperpolarized 3He MRI study.
Early changes of lung function and structure were studied in the presence of an elastase-induced model of emphysema in 35 Sprague-Dawley rats at mild (5 U/100 g) and moderate (10 U/100 g) severities. Lung ventilation was measured on a regional basis (at a planar resolution of 3.2 mm) by hyperpolarized 3He MRI at 5 and 10 wk after model induction. Subsequent to imaging, average alveolar diameter...
متن کاملExploration of multi-volumetric hyperpolarized 3Helium MRI: cross-correlation with quantitative MDCT
Pulmonary ventilation is a complex physiological phenomenon controlling the gas exchange process, through localized physiological responses. Detection of regional changes that occur with the onset of early disease conditions and changes occurring over short time intervals are of increasing importance as imaging is applied to the evaluation of the efficacy and safety associated with surgical and...
متن کاملFunctional analysis in single-lung transplant recipients: a comparative study of high-resolution CT, 3He-MRI, and pulmonary function tests.
OBJECTIVE To develop and evaluate a postprocessing tool to quantify ventilated split-lung volumes on the basis of (3)He-MRI and to apply it in patients after single-lung transplantation (SLTX). High-resolution CT (HRCT) was employed as a reference modality providing split air-filled lung volumes. Lung volumes derived from pulmonary function test results served as clinical parameters and were us...
متن کاملEvaluating bronchodilator effects in chronic obstructive pulmonary disease using diffusion-weighted hyperpolarized helium-3 magnetic resonance imaging.
The objective of this study was to evaluate the regional effects of bronchodilator administration in chronic obstructive pulmonary disease (COPD) using hyperpolarized helium-3 ((3)He) MRI apparent diffusion coefficient (ADC). Ten COPD ex-smokers provided written, informed consent and underwent diffusion-weighted, hyperpolarized (3)He MRI, spirometry, and plethysmography before and 25 ± 2 min af...
متن کاملComparison of 3 He and 129 Xe MRI for evaluation of lung microstructure and ventilation at 1.5T.
BACKGROUND To support translational lung MRI research with hyperpolarized 129 Xe gas, comprehensive evaluation of derived quantitative lung function measures against established measures from 3 He MRI is required. Few comparative studies have been performed to date, only at 3T, and multisession repeatability of 129 Xe functional metrics have not been reported. PURPOSE/HYPOTHESIS To compare hy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 110 1 شماره
صفحات -
تاریخ انتشار 2011