Radiation dose reduction strategy for CT protocols: successful implementation in neuroradiology section.

نویسندگان

  • Alice B Smith
  • William P Dillon
  • Benison C Lau
  • Robert Gould
  • Francis R Verdun
  • Edward B Lopez
  • Max Wintermark
چکیده

PURPOSE To retrospectively quantify the effect of systematic use of tube current modulation for neuroradiology computed tomographic (CT) protocols on patient dose and image quality. MATERIALS AND METHODS This HIPAA-compliant study had institutional review board approval, with waiver of informed consent. The authors evaluated the effect of dose modulation on four types of neuroradiologic CT studies: brain CT performed without contrast material (unenhanced CT) in adult patients, unenhanced brain CT in pediatric patients, adult cervical spine CT, and adult cervical and intracranial CT angiography. For each type of CT study, three series of 100 consecutive studies were reviewed: 100 studies performed without dose modulation, 100 studies performed with z-axis dose modulation, and 100 studies performed with x-y-z-axis dose modulation. For each examination, the weighted volume CT dose index (CTDI(vol)) and dose-length product (DLP) were recorded and noise was measured. Each study was also reviewed for image quality. Continuous variables (CTDI(vol), DLP, noise) were compared by using t tests, and categorical variables (image quality) were compared by using Wilcoxon rank-sum tests. RESULTS For unenhanced CT of adult brains, the CTDI(vol) and DLP, respectively, were reduced by 60.9% and 60.3%, respectively, by using z-axis dose modulation and by 50.4% and 22.4% by using x-y-z-axis dose modulation. Significant dose reductions (P < .001) were also observed for pediatric unenhanced brain CT, cervical spine CT, and adult cervical and intracranial CT angiography performed with each dose modulation technique. Image quality and noise were unaffected by the use of either dose modulation technique (P > .05). CONCLUSION Use of dose-modulation techniques for neuroradiology CT examinations affords significant dose reduction while image quality is maintained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of eye lens dose on neuroimaging protocols between 16- and 64-section multidetector CT: achieving the lowest possible dose.

BACKGROUND AND PURPOSE To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols. MATERIALS AND METHODS ...

متن کامل

Strategy of computed tomography image optimization in cervical vertebra and neck soft tissue in emergency patients

Introduction: Due to the use of ionizing radiation in the CT scan, optimal parameters should be used to reduce the risk of cancer in patients who are constantly exposed to X-rays. The aim of this study was to optimize the parameters used in CT scan of cervical vertebrae and neck soft tissue with minimal loss of image quality   Materials and Methods: In this s...

متن کامل

Radiation dose-reduction strategies for neuroradiology CT protocols.

Within the past 2 decades, the number of CT examinations performed has increased almost 10-fold. This is in large part due to advances in multidetector-row CT technology, which now allows faster image acquisition and improved isotropic imaging. The increased use, along with multidetector technique, has led to a significantly increased radiation dose to the patient from CT studies. This places i...

متن کامل

Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose

Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...

متن کامل

Raise the bar and lower the dose: current and future strategies for radiation dose reduction in head and neck imaging.

SUMMARY Technologic advances in CT have generated a dramatic increase in the number of CT studies, with a resultant increase in the radiation dose related to CT scanning. Such increase in radiation dose is becoming a concern for the radiology community, especially with increasing public awareness of the dose burden related to examinations. To cope with the increase in CT-related radiation expos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 247 2  شماره 

صفحات  -

تاریخ انتشار 2008