A Real-Time Pulse Peak Detection Algorithm for the Photoplethysmogram

نویسندگان

  • Dae-Geun Jang
  • Sangjun Park
  • Minsoo Hahn
  • Seung-Hun Park
چکیده

In this paper, we propose a simple and low complexity pulse peak detection algorithm using cascaded recursive digital filters and a slope sum function (SSF) with an adaptive thresholding scheme. The algorithm first eliminates noises in the photoplethysmogram (PPG) using the cascaded lowpass and highpass digital filters. The filters have been designed with 3-dB cutoff frequencies of 11 Hz and 0.5 Hz, respectively. The filtered PPG signal is then transformed by the SSF. The SSF simplifies detecting the pulse peaks by enhancing the upslope of the PPG signal and suppressing the remainder. A threshold for identifying SSF peaks is updated using the median filter with an order of 5. This update makes the threshold adaptive to variations of SSF heights. The detected SSF peaks localize ranges for pulse peak detection. Finally, the pulse peak is identified by picking the local maxima within the range from an onset index of the SSF signal to the following zero index. In order to cope with over-detected and missed information, the proposed algorithm employs knowledge-based rules as postprocessing. The algorithm is tested on a database where PPG waveforms are collected from 127 subjects. The results are promising, suggesting that the method provides simpler but accurate pulse peak detection in real applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification the Effect of Ageing on Characteristics of the Photoplethysmogram Using an Optimized Windkessel Model

Background: With increasing age, some changes appeared in specifications of vessels which including dimensions and elasticity in their. The changes in parameters such as resistance, inertance and compliance vessels appear and eventually changes in the environmental pulse releases are in circulation. These changes clearly appear in specification of photoplethysmogram particularly in the size and...

متن کامل

Extending the Radar Dynamic Range using Adaptive Pulse Compression

The matched filter in the radar receiver is only adapted to the transmitted signal version and its output will be wasted due to non-matching with the received signal from the environment. The sidelobes amplitude of the matched filter output in pulse compression radars are dependent on the transmitted coded waveforms that extended as much as the length of the code on both sides of the target loc...

متن کامل

An Efficient and Automatic Systolic Peak Detection Algorithm for Photoplethysmographic Signals

Processing of physiological signals often involves detection of peaks and finding intervals between them. Well developed methods are available for Electrocardiogram(ECG) QRS complex detection. However, there are only a few algorithms published for peak detection suitable for pulse wave signals such as arterial pressure wave and photoplethysmographic (PPG) signals. Algorithms for detection of QR...

متن کامل

Assessment of Photoplethysmography Method in Extraction of Hemoglobin Concentration

Background: The importance of continuous monitoring along with rapid and accurate notification of changes in blood components such as hemoglobin concentration, especially in acute situations, encourages researchers to use non-invasive methods for measuring.Objective: This study was aimed to investigate the correlation between hemoglobin concentration and photoplethysmogram (PPG) and the p...

متن کامل

Systolic Peak Detection in Acceleration Photoplethysmograms Measured from Emergency Responders in Tropical Conditions

Photoplethysmogram (PPG) monitoring is not only essential for critically ill patients in hospitals or at home, but also for those undergoing exercise testing. However, processing PPG signals measured after exercise is challenging, especially if the environment is hot and humid. In this paper, we propose a novel algorithm that can detect systolic peaks under challenging conditions, as in the cas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014