Evaluation of MGIT 960 System for the Second-Line Drugs Susceptibility Testing of Mycobacterium tuberculosis

نویسندگان

  • Hyejin Kim
  • Minji Seo
  • Young Kil Park
  • Jae-Il Yoo
  • Yeong Seon Lee
  • Gyung Tae Chung
  • Sungweon Ryoo
چکیده

Many laboratories validate DST of the second-line drugs by BACTEC MGIT 960 system. The objective of this study is to evaluate the critical concentration and perform DST for the 2nd line drugs. We evaluated 193 clinical strains of M. tuberculosis isolated from patients in South Korea. Testing the critical concentration of six second-line drugs was performed by MGIT 960 and compared with L-J proportion method. The critical concentration was determined to establish the most one that gave the difference between drug resistance and susceptibility in MGIT960 system. Good agreement of the following concentrations was found: Concordance was 95% for 0.5  μ g/mL of moxifloxacin; 93.6%, 1.0  μ g/mL of levofloxacin; 97.5%, 2.5  μ g/mL of kanamycin; 90.6%, 2.5  μ g/mL of capreomycin; 86.2%, 5.0  μ g/mL of ethionamide; and 90.8%, 2.0  μ g/mL of ρ-aminosalicylic acid. The critical concentrations of the four drugs, moxifloxacin, levofloxacin, kanamycin, and capreomycin, were concordant and reliable for testing 2nd line drug resistance. Further study of ethionamide and ρ -aminosalicylic acid is required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of BACTEC MGIT 960 system for the second-line drugs susceptibility testing of Mycobacterium tuberculosis in China.

When the performance of the BACTEC MGIT 960 system was evaluated with the traditional proportion method (PM) on 321 clinical isolates of Mycobacterium tuberculosis from China, concordance values were 98.44% capreomycin, 98.75% kanamycin, 98.75% ofloxacin and 94.08% ethionamide. The turnaround time with BACTEC MGIT 960 system (7.5±1.8 days) was significantly shorter than with PM (28 days or 42 d...

متن کامل

Multicenter laboratory validation of the BACTEC MGIT 960 technique for testing susceptibilities of Mycobacterium tuberculosis to classical second-line drugs and newer antimicrobials.

The BACTEC MGIT 960 system, a fully automated, nonradiometric, noninvasive system for detection and drug susceptibility testing of mycobacteria, was evaluated for the ability to test susceptibilities to second-line drugs. In this study, which was carried out in three phases (phase I, mostly susceptible strains; phase II, mostly resistant strains; phase III, final testing of the optimal drug con...

متن کامل

Multicenter evaluation of fully automated BACTEC Mycobacteria Growth Indicator Tube 960 system for susceptibility testing of Mycobacterium tuberculosis.

The reliability of the BACTEC Mycobacteria Growth Indicator Tube (MGIT) 960 system for testing of Mycobacterium tuberculosis susceptibility to the three front-line drugs (isoniazid [INH], rifampin [RIF], and ethambutol [EMB]) plus streptomycin (STR) was compared to that of the BACTEC 460 TB system. The proportion method was used to resolve discrepant results by an independent arbiter. One hundr...

متن کامل

Antimicrobial susceptibility testing of Mycobacterium tuberculosis to first-line drugs: comparisons of the MGIT 960 and BACTEC 460 systems.

The reliability of the Mycobacteria Growth Indicator Tube (MGIT) 960 system for rapid antimicrobial susceptibility testing (AST) of Mycobacterium tuberculosis was evaluated. Forty-seven isolates, including 10 fully susceptible and 37 resistant strains, were tested for susceptibility to the critical concentrations of streptomycin (STR), isoniazid (INH), rifampin (RMP), and ethambutol (EMB), as r...

متن کامل

Evaluation of BACTEC Mycobacteria Growth Indicator Tube (MGIT 960) automated system for drug susceptibility testing of Mycobacterium tuberculosis.

The reliability of the BACTEC MGIT 960 system, an automated version of the Mycobacteria Growth Indicator Tube (MGIT), for antimicrobial susceptibility testing of Mycobacterium tuberculosis was evaluated on 78 clinical isolates. Rifampin (RMP), isoniazid (INH), streptomycin (SM), and ethambutol (EMB) were tested at the following concentrations: 1.0 microg/ml for RMP, 0.1 and 0.4 microg/ml for IN...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013