What ’ s the Most Meaningful Standard for Mass Spectrometry : Instrument Detection Limit or Signal - to - Noise Ratio ?
نویسندگان
چکیده
Terry L. Sheehan and Richard A. Yost When evaluating the performance of mass spectrometers, one needs to consider the best (or most meaningful) figure of merit to use; options include instrument detection limit (IDL) and signal-tonoise ratio (SNR). In the last 15 years, vendor specifications for SNR have increased from 10:1 to greater than 100,000:1. Does that accurately reflect improvements in mass spectrometers? Although there have been many significant changes, the change in SNR specifications has been far greater than the corresponding change in method detection limits (MDL). Under appropriate conditions, SNR is a meaningful standard, but the value of any SNR must be evaluated in context of the chromatography and sample. Factors influencing the validity of vendor SNR specifications are reviewed, and the statistical alternative of IDL is presented as a replacement that is more consistent with regulatory guidelines and a more relevant indicator of instrument performance. What’s the Most Meaningful Standard for Mass Spectrometry: Instrument Detection Limit or Signal-to-Noise Ratio?
منابع مشابه
Why use Signal-To-Noise as a Measure of MS Performance When it is Often Meaningless?
The signal-to-noise of a chromatographic peak determined from a single measurement has served as a convenient figure of merit used to compare the performance of two different MS systems. The evolution in the design of mass spectrometry instrumentation has resulted in very low noise systems that have made the comparison of performance based upon signal-to-noise increasingly difficult, and in som...
متن کاملDerivatization and Gas Chromatography– Low-resolution Mass Spectrometry of Bisphenol A
Gas chromatography–mass spectrometry (GC–MS) has been investigated for identification of bisphenol A (BPA) at ppb levels in biological samples. Initially a limit of detection (LOD) of 600 ppb BPA was established by direct selected-ion monitoring (SIM) GC–MS. Next, standard solutions of BPA and extracts of powdered milk were derivatized with two different reagents – N,O-bis-(trimethylsilyl)trifl...
متن کاملIntensity of the internal standard response as the basis for reporting a test specimen as negative or inconclusive.
Under normal circumstances, a test specimen is reported as "negative" when the response of the analyte is absent. However, if the intensity of the internal standard (IS) is low, indicating interference factors, the test could be considered "inconclusive." A quantitative hypothesis, A=(R x I x S)/L, serves as the "cutoff" for the acceptable signal-to-noise (S/N) ratio for the IS in making "negat...
متن کاملEdge Detection Based On Nearest Neighbor Linear Cellular Automata Rules and Fuzzy Rule Based System
Edge Detection is an important task for sharpening the boundary of images to detect the region of interest. This paper applies a linear cellular automata rules and a Mamdani Fuzzy inference model for edge detection in both monochromatic and the RGB images. In the uniform cellular automata a transition matrix has been developed for edge detection. The Results have been compared to the ...
متن کاملEdge Detection Based On Nearest Neighbor Linear Cellular Automata Rules and Fuzzy Rule Based System
Edge Detection is an important task for sharpening the boundary of images to detect the region of interest. This paper applies a linear cellular automata rules and a Mamdani Fuzzy inference model for edge detection in both monochromatic and the RGB images. In the uniform cellular automata a transition matrix has been developed for edge detection. The Results have been compared to the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017