Fabry-Perot interferometer with quantum mirrors: nonlinear light transport and rectification.

نویسندگان

  • F Fratini
  • E Mascarenhas
  • L Safari
  • J-Ph Poizat
  • D Valente
  • A Auffèves
  • D Gerace
  • M F Santos
چکیده

Optical transport represents a natural route towards fast communications, and it is currently used in large scale data transfer. The progressive miniaturization of devices for information processing calls for the microscopic tailoring of light transport and confinement at length scales appropriate for upcoming technologies. With this goal in mind, we present a theoretical analysis of a one-dimensional Fabry-Perot interferometer built with two highly saturable nonlinear mirrors: a pair of two-level systems. Our approach captures nonlinear and nonreciprocal effects of light transport that were not reported previously. Remarkably, we show that such an elementary device can operate as a microscopic integrated optical rectifier.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantum theory of high-resolution length measurement with a Fabry-Perot interferometer

The quantum limits on measurements of small changes in the length of a Fabry-Perot cavity are calculated . The cavity is modelled by a pair of dissimilar mirrors oriented perpendicular to a one-dimensional axis of infinite extent . The continuous spectrum of spatial modes of the system is derived, and the electromagnetic field is quantized in terms of a continuous set of mode creation and destr...

متن کامل

Shot noise in gravitational-wave detectors with Fabry-Perot arms.

Shot-noise-limited sensitivity is calculated for gravitational-wave interferometers with Fabry-Perot arms, similar to those being installed at the Laser Interferometer Gravitational-Wave Observatory (LIGO) and the Italian-French Laser Interferometer Collaboration (VIRGO) facility. This calculation includes the effect of nonstationary shot noise that is due to phase modulation of the light. The ...

متن کامل

Estimating the off resonance thermal noise in mirrors, Fabry-Perot interferometers, and delay lines: The half infinite mirror with uniform loss

We present an analysis comparing the thermal noise in Fabry-Perot and delay-line interferometers with half-infinite mirrors. With a center to center spot spacing of at least twice the Gaussian beam spot size a delay line produces significantly less phase noise than a comparable Fabry-Perot interferometer for the case of half infinite mirrors at frequencies where test mass thermal noise usually ...

متن کامل

Two-Dimensional Nonlinear Fabry-Perot Interferometer: An Unconventional Computing Substrate for Maze Exploration and Logic Gate Operation

This study examined a possibility to use a two-dimensional nonlinear Fabry-Perot interferometer (2DNFP) as a novel information processing device. Optical bistability was realized through positive or negative feedback between heat generated by absorption of light and change in resonance condition induced by temperaturedependent refractive index. Due to heat conduction in lateral direction, “turn...

متن کامل

Chitosan Layer Fabry - Perot Interferometer - Based Optical Fiber Sensor for Cadmium Ion Detection

Optical sensors based on Fabry-Perot interferometer to detect cadmium ions is proposed. The sensor was fabricated by coating the tip of the optical fiber by chitosan. The two chitosan surfaces serve as mirrors which form a Fabry-Perot interferometer. The characterization results indicate that the sensor has a linear response with sensitivity of 0.0884 dBm/ppm with a correlation factor of 0.9665...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 113 24  شماره 

صفحات  -

تاریخ انتشار 2014