MR angiography of dural arteriovenous fistulas: diagnosis and follow-up after treatment using a time-resolved 3D contrast-enhanced technique.

نویسندگان

  • S Meckel
  • M Maier
  • D San Millan Ruiz
  • H Yilmaz
  • K Scheffler
  • E-W Radue
  • S G Wetzel
چکیده

BACKGROUND AND PURPOSE Digital subtraction angiography (DSA) is the method of reference for imaging of dural arteriovenous fistula (DAVF). The goal of this study was to analyze the value of different MR images including 3D contrast-enhanced MR angiography (MRA) with a high temporal resolution in diagnostic and follow-up imaging of DAVFs. MATERIALS AND METHODS A total of 18 MR/MRA examinations from 14 patients with untreated (n=9) and/or treated (n=9) DAVFs were evaluated. Two observers assessed all MR and MRA investigations for signs indicating the presence of a DAVF, for fistula characteristics such as fistula grading, location of fistulous point, and fistula obliteration after treatment. All results were compared with DSA findings. RESULTS On time-resolved 3D contrast-enhanced (TR 3D) MRA, the side and presence of all patent fistulas (n=13) were correctly indicated, and no false-positive findings were observed in occluded DAVFs (n=5). Grading of fistulas with this imaging technique was correct in 77% and 85% of patent fistulas for both readers, respectively. On T2-weighted images, signs indicative of a DAVF were encountered only in fistulas with cortical venous reflux (56%), whereas on 3D time-of-flight (TOF) MRA, most fistulas (88%) were correctly detected. In complete fistula occlusion, false-positive findings were encountered on both T2-weighted images and on TOF MRA images. CONCLUSION In this study, TR 3D MRA proved reliable in detecting DAVFs and suitable for follow-up imaging. The technique allowed--within limitations--to grade DAVFs. Although 3D TOF MRA can depict signs of DAVFs, its value for follow-up imaging is limited.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-resolved contrast-enhanced MR angiography of spinal vascular malformations.

BACKGROUND AND PURPOSE The diagnosis of spinal vascular malformations may be challenging on conventional MR imaging because neither the location of the signal abnormality in the spinal cord nor the level of the abnormal flow voids correlates with the level of the fistula. We conducted a retrospective evaluation of the utility of using a time-resolved imaging of contrast kinetics sequence in the...

متن کامل

Magnetic Resonance Angiography in the Diagnosis of Cerebral Arteriovenous Malformation and Dural Arteriovenous Fistulas: Comparison of Time-Resolved Magnetic Resonance Angiography and Three Dimensional Time-of-Flight Magnetic Resonance Angiography

BACKGROUND Traditional digital subtraction angiography (DSA) is currently the gold standard diagnostic method for the diagnosis and evaluation of cerebral arteriovenous malformation (AVM) and dural arteriovenous fistulas (dAVF). OBJECTIVES The aim of this study was to analyze different less invasive magnetic resonance angiography (MRA) images, time-resolved MRA (TR-MRA) and three-dimensional ...

متن کامل

2D Thick-section MR digital subtraction angiography for the assessment of dural arteriovenous fistulas.

BACKGROUND AND PURPOSE Although dynamic contrast-enhanced MR angiography studies for arteriovenous malformations (AVFs) and brain tumors have shown promising results, no formal attempt has yet been made to similarly evaluate dural AVFs. To assess the practical applicability of 2D thick-section contrast enhanced MR digital subtraction angiography (MRDSA) for the diagnosis and management of dural...

متن کامل

MR Visualization of Spinal Dural Arterio-Venous Fistula Using T2-Weighted 3D SPACE—A Spin-Echo Technique

Spinal dural arteriovenous fistulas (SDAVF) account for about 70% of all spinal AV shunts. We report on a 56-year-old male patient with progressive neurological symptoms. Preand post-contrast MR imaging of the spine, including contrast-enhanced MR angiography was done on a 1.5 T MR scanner. In addition a special (pre-contrast) 3D turbo-spin-echo sequence with variable flip angle evolution (SPAC...

متن کامل

Assessment of dural arteriovenous fistulas of the cavernous sinuses on 3D dynamic MR angiography.

BACKGROUND AND PURPOSE Flow voids within the cavernous sinuses and/or certain venous drainage on spin-echo MR imaging and time-of-flight (TOF) flow enhancement on MR angiography (MRA) have indicated high-velocity shunt flow and have been used for screening patients with dural arteriovenous fistulas (DAVFs) of the cavernous sinuses. In this investigation, the capabilities of 3D dynamic MRA as a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 2007