A generalized quantitative interpretation of dark-field contrast for highly concentrated microsphere suspensions

نویسندگان

  • Spyridon Gkoumas
  • Pablo Villanueva-Perez
  • Zhentian Wang
  • Lucia Romano
  • Matteo Abis
  • Marco Stampanoni
چکیده

In X-ray grating interferometry, dark-field contrast arises due to partial extinction of the detected interference fringes. This is also called visibility reduction and is attributed to small-angle scattering from unresolved structures in the imaged object. In recent years, analytical quantitative frameworks of dark-field contrast have been developed for highly diluted monodisperse microsphere suspensions with maximum 6% volume fraction. These frameworks assume that scattering particles are separated by large enough distances, which make any interparticle scattering interference negligible. In this paper, we start from the small-angle scattering intensity equation and, by linking Fourier and real-space, we introduce the structure factor and thus extend the analytical and experimental quantitative interpretation of dark-field contrast, for a range of suspensions with volume fractions reaching 40%. The structure factor accounts for interparticle scattering interference. Without introducing any additional fitting parameters, we successfully predict the experimental values measured at the TOMCAT beamline, Swiss Light Source. Finally, we apply this theoretical framework to an experiment probing a range of system correlation lengths by acquiring dark-field images at different energies. This proposed method has the potential to be applied in single-shot-mode using a polychromatic X-ray tube setup and a single-photon-counting energy-resolving detector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial dark-field microscopy for investigating domain structures of double-layer microsphere film

A lateral dislocation in a double-layer microsphere film is very difficult to identify because the constituent domains have the same two-dimensional crystalline orientation. Orientation-sensitive optical techniques cannot resolve this issue. Here, we demonstrate that partial dark-field (pDF) optical microscopy can be very effective in identifying this type of domain boundary and dislocation of ...

متن کامل

Fluid dynamics of bacterial turbulence.

Self-sustained turbulent structures have been observed in a wide range of living fluids, yet no quantitative theory exists to explain their properties. We report experiments on active turbulence in highly concentrated 3D suspensions of Bacillus subtilis and compare them with a minimal fourth-order vector-field theory for incompressible bacterial dynamics. Velocimetry of bacteria and surrounding...

متن کامل

Yield stress in magnetorheological suspensions near the limit of maximum-packing fraction

This work deals with the magnetic field-induced static yield stress of magnetorheological (MR) suspensions with concentration near the limit of maximum-packing fraction. With this aim, homogeneous suspensions of iron microparticles with 50 vol.% concentration were prepared, and their yield stress measured as a function of the applied magnetic field. In view of the failure of existing models to ...

متن کامل

Artifacts in X-ray Dark-Field Tomography

Grating-based x-ray imaging provides three principle kinds of contrast: absorption, phase, and dark-field. Due to the availability of tomographic reconstruction algorithms for the dark-field contrast, it is now possible to take advantage of quantitative scatter information. However, the published algorithm is based on several assumptions that might be violated in reality. We use numerical simul...

متن کامل

Optical scatter imaging: subcellular morphometry in situ with Fourier filtering.

We demonstrate a quantitative optical scatter imaging (OSI) technique, based on Fourier filtering, for detecting alterations in the size of particles with wavelength-scale dimensions. We generate our scatter image by taking the ratio of images collected at high and low numerical aperture in central dark-field microscopy. Such an image spatially encodes the ratio of wide to narrow angle scatter ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016