The Application of Digital Pathology to Improve Accuracy in Glomerular Enumeration in Renal Biopsies

نویسندگان

  • Avi Z. Rosenberg
  • Matthew Palmer
  • Lino Merlino
  • Jonathan P. Troost
  • Adil Gasim
  • Serena Bagnasco
  • Carmen Avila-Casado
  • Duncan Johnstone
  • Jeffrey B. Hodgin
  • Catherine Conway
  • Brenda W. Gillespie
  • Cynthia C. Nast
  • Laura Barisoni
  • Stephen M. Hewitt
چکیده

BACKGROUND In renal biopsy reporting, quantitative measurements, such as glomerular number and percentage of globally sclerotic glomeruli, is central to diagnostic accuracy and prognosis. The aim of this study is to determine the number of glomeruli and percent globally sclerotic in renal biopsies by means of registration of serial tissue sections and manual enumeration, compared to the numbers in pathology reports from routine light microscopic assessment. DESIGN We reviewed 277 biopsies from the Nephrotic Syndrome Study Network (NEPTUNE) digital pathology repository, enumerating 9,379 glomeruli by means of whole slide imaging. Glomerular number and the percentage of globally sclerotic glomeruli are values routinely recorded in the official renal biopsy pathology report from the 25 participating centers. Two general trends in reporting were noted: total number per biopsy or average number per level/section. Both of these approaches were assessed for their accuracy in comparison to the analogous numbers of annotated glomeruli on WSI. RESULTS The number of glomeruli annotated was consistently higher than those reported (p<0.001); this difference was proportional to the number of glomeruli. In contrast, percent globally sclerotic were similar when calculated on total glomeruli, but greater in FSGS when calculated on average number of glomeruli (p<0.01). The difference in percent globally sclerotic between annotated and those recorded in pathology reports was significant when global sclerosis is greater than 40%. CONCLUSIONS Although glass slides were not available for direct comparison to whole slide image annotation, this study indicates that routine manual light microscopy assessment of number of glomeruli is inaccurate, and the magnitude of this error is proportional to the total number of glomeruli.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical, Histopathological and Immunofluorescent Findings of IgA Nephropathy

Background: IgA nephropathy, a prevalent disease in Asia, is considered the main cause of end stage renal disease among primary glomerular disease. Objective: To determine the frequency of different clinical, histopathological and immunofluorescent characteristics of IgA nephropathy. Methods: Renal biopsies of 376 patients were received for immunofluorescent and for histopathological studies. B...

متن کامل

Digital pathology evaluation of complement C4d component deposition in the kidney allograft biopsies is a useful tool to improve reproducibility of the scoring

Complement C4d component deposition in kidney allograft biopsies is an established marker of antibody-mediated rejection. In the Banff 07 classification of renal allograft pathology, semi-quantitative evaluation of the proportion of C4d-positive peritubular capilaries (PTC) is used. We aimed to explore the potential of digital pathology tools to obtain quantitative and reproducible measure of C...

متن کامل

شیوع نفروپاتی IgA در بیماران مبتلا به گلومرولونفریت اولیه

During a 14-month period (Dec. 1990-Jan. 1992) , renal biopsies were performed on 105 patients with suspected glomerular disease. All specimens were processed for light microscopy (L.M) and immunoflourescence. Work-up revealed 21 patients to suffer a systemic glomerular disease and glomerular disease was found to be primery in 85 cases. Predominant IgG deposition was noted in 71 cases with prim...

متن کامل

Efficacy of Pseudocolor Tool of Digital System in the Detection of Proximal Caries

Introduction: Various intraoral digital radiographic systems are available as an alternative to film-based radiography. Recent rapid progress in the field of digital radiography offers the possibility of image processing and manipulation. Pseudocolor filter is one of the tools of digital systems. The aim of this study was to compare diagnostic accuracy of proximal caries in black and white a...

متن کامل

Evaluation of Possible Role of Dendritic Cells in Various Lupus Nephritis

Background & Objectives: Chronicity of lupus nephritis (LN) should be considered for interaction of cell mediated immunity (CMI) and dendritic cells in glomeruli and tubulointerstitial areas. In this study establishment of immunohistopathological changes of dendritic cells and other immune effector cells in lupus nephritis comparing with non-lupus nephritis was performed. Materials & Methods: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016