چکیده

BACKGROUND This study aimed to determine whether QRS morphology identifies patients who benefit from cardiac resynchronization therapy with a defibrillator (CRT-D) and whether it influences the risk of primary and secondary end points in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) trial. METHODS AND RESULTS Baseline 12-lead ECGs were evaluated with regard to QRS morphology. Heart failure event or death was the primary end point of the trial. Death, heart failure event, ventricular tachycardia, and ventricular fibrillation were secondary end points. Among 1817 patients with available sinus rhythm ECGs at baseline, there were 1281 (70%) with left bundle-branch block (LBBB), 228 (13%) with right bundle-branch block, and 308 (17%) with nonspecific intraventricular conduction disturbances. The latter 2 groups were defined as non-LBBB groups. Hazard ratios for the primary end point for comparisons of CRT-D patients versus patients who only received an implantable cardioverter defibrillator (ICD) were significantly (P < 0.001) lower in LBBB patients (0.47; P < 0.001) than in non-LBBB patients (1.24; P = 0.257). The risk of ventricular tachycardia, ventricular fibrillation, or death was decreased significantly in CRT-D patients with LBBB but not in non-LBBB patients. Echocardiographic parameters showed significantly (P < 0.001) greater reduction in left ventricular volumes and increase in ejection fraction with CRT-D in LBBB than in non-LBBB patients. CONCLUSIONS Heart failure patients with New York Heart Association class I or II and ejection fraction ≤ 30% and LBBB derive substantial clinical benefit from CRT-D: a reduction in heart failure progression and a reduction in the risk of ventricular tachyarrhythmias. No clinical benefit was observed in patients with a non-LBBB QRS pattern (right bundle-branch block or intraventricular conduction disturbances). CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac resynchronization therapy is more effective in women than in men: the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy) trial.

OBJECTIVES The purpose of this study was to investigate the factors related to sex-specific outcomes for death and heart failure events in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) trial. BACKGROUND In the MADIT-CRT trial, women seemed to achieve a better result from resynchronization therapy than men. METHODS All 1,820 pat...

متن کامل

Cardiac resynchronization therapy reduces left atrial volume and the risk of atrial tachyarrhythmias in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy).

OBJECTIVES We hypothesized that reductions in left atrial volume (LAV) with a cardiac resynchronization therapy-defibrillator (CRT-D) would translate into a subsequent reduction in the risk of atrial tachyarrhythmias (AT). BACKGROUND There is limited information regarding the effect of CRT-D on the risk of AT. METHODS Percent reduction in LAV at 1 year following CRT-D implantation (pre-spec...

متن کامل

Heart Failure Predictors of Response to Cardiac Resynchronization Therapy in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT)

Background—We hypothesized that combined assessment of factors that are associated with favorable reverse remodeling after cardiac resynchronization-defibrillator therapy (CRT-D) can be used to predict clinical response to the device. Methods and Results—The study population comprised 1761 patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchroniza...

متن کامل

Cardiac resynchronization therapy reduces the risk of cardiac events in patients with diabetes enrolled in the multicenter automatic defibrillator implantation trial with cardiac resynchronization therapy (MADIT-CRT).

BACKGROUND Data are limited regarding whether the presence of diabetes mellitus (DM) influences the benefit of cardiac resynchronization with defibrillator therapy (CRT-D) in heart failure (HF) patients. METHODS AND RESULTS The effect of CRT-D was evaluated in 1817 patients who were enrolled in the Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (...

متن کامل

Cardiac resynchronization therapy for mild heart failure: the time has come.

Current guidelines recommend cardiac resynchronization therapy (CRT), previously known as biventricular pacing, in patients with left ventricular (LV) systolic dysfunction (ejection fraction [EF] 35%), QRS prolongation ( 120 ms), and New York Heart Association (NYHA) class III or IV heart failure (HF).1 These recommendations come after multiple prospective, randomized trials demonstrated the be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 123 10  شماره 

صفحات  -

تاریخ انتشار 2011